2018
DOI: 10.1016/j.scitotenv.2017.12.048
|View full text |Cite
|
Sign up to set email alerts
|

Influence of solid-liquid separation method parameters employed in soil leaching tests on apparent metal concentration

Abstract: Soil leaching tests are commonly used to evaluate the leachability of hazardous materials, such as heavy metals, from the soil. Batch leaching tests often enhance soil colloidal mobility and may require solid-liquid separation procedures to remove excess soil particles. However, batch leaching test results depend on particles that can pass through a 0.45μm membrane filter and are influenced by test parameters such as centrifugal intensity and filtration volume per filter. To evaluate these parameters, we condu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
8
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(9 citation statements)
references
References 13 publications
1
8
0
Order By: Relevance
“…Importantly, these results confirm previous reports that the 0.45 µm filter is not sufficient to completely remove suspended particles, which affects evaluations of the mobility of certain toxic elements such as Pb (e.g., Yasutaka et al 2017;Imoto et al 2018;Ito et al 2018).…”
Section: Factors Controlling the Dissolved Concentrations Of Toxic Elsupporting
confidence: 89%
“…Importantly, these results confirm previous reports that the 0.45 µm filter is not sufficient to completely remove suspended particles, which affects evaluations of the mobility of certain toxic elements such as Pb (e.g., Yasutaka et al 2017;Imoto et al 2018;Ito et al 2018).…”
Section: Factors Controlling the Dissolved Concentrations Of Toxic Elsupporting
confidence: 89%
“…Colloids could have passed through the filter during the liquid-solid separation step, and so may have affected the measured concentrations in the eluate [ 28 , 29 , 30 ]. To confirm the effect of colloids, eluates obtained using a 0.45 μm pore size filter (0.45 MF) were refiltered using a 0.1 μm pore size filter.…”
Section: Resultsmentioning
confidence: 99%
“…This suggests that in smaller LS conditions, colloids of 0.45 μm or smaller were removed at the first filtration by the cake that formed on 0.45 MF, but in larger LS conditions, such cake did not foam sufficiently to remove the colloids. Subsequent refiltration using 0.1 MF was able to remove colloids of 0.1–0.45 mm, resulting in significant reductions of their concentrations in the eluates [ 28 ]. Furthermore, in LS 300 it may have been difficult to remove colloids of 0.1 μm or smaller during refiltration, as the resulting concentration was higher and the observed variation was larger than those of LS 100.…”
Section: Resultsmentioning
confidence: 99%
“…Leachates were collected daily and divided into two aliquots. No filtration procedure was applied to avoid the removal of analytes bound to colloidal phases [8]. The first aliquot was acidified with 3% HNO 3 for TMs analysis.…”
Section: Experimental Design Materials and Methodsmentioning
confidence: 99%