2013
DOI: 10.1016/j.procir.2013.01.038
|View full text |Cite
|
Sign up to set email alerts
|

Influence of Stress on the Degradation Behavior of Mg LAE442 Implant Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
6
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(7 citation statements)
references
References 5 publications
1
6
0
Order By: Relevance
“…This bone formation occurred over the devices, 447where periosteal and muscle tissue layers are typically present,448 suggesting the ability of Mg-ion release from device degradation 449 to affect osteoblastic cell differentiation. This observation is in450 accordance with our previous study in which de novo bone formation was observed around Mg plates and screws after 4 weeks[21], as well as a previous report of LAE442 screws and plates implanted453 in intact rabbit tibia[36]. With the present study, we have confirmed our pilot study observations, and demonstrated that prolonged exposure to Mg degradation can cause progressive bone456 formation.…”
supporting
confidence: 92%
“…This bone formation occurred over the devices, 447where periosteal and muscle tissue layers are typically present,448 suggesting the ability of Mg-ion release from device degradation 449 to affect osteoblastic cell differentiation. This observation is in450 accordance with our previous study in which de novo bone formation was observed around Mg plates and screws after 4 weeks[21], as well as a previous report of LAE442 screws and plates implanted453 in intact rabbit tibia[36]. With the present study, we have confirmed our pilot study observations, and demonstrated that prolonged exposure to Mg degradation can cause progressive bone456 formation.…”
supporting
confidence: 92%
“…The original HP-Mg staple was designed according to the clinical used U-shape titanium staple. Considering the high stress corrosion sensitivity of magnesium [9] , [10] , [11] , the interior angles of the modified staple were designed to 100°. The closure of the staples were performed through the linear cutter stapler (MLC-60, Nanjing Maidixin Medical Device Co., Ltd. China).…”
Section: Methodsmentioning
confidence: 99%
“…Though Mg and its alloys have so many merits, medical transformation is still having a long way to go. The Mg-based bone plates, for example, bone plate and screws made of the LAE442 alloy were shown to severely corrode in the bone plate/screws contact area, which is attributed to the localized corrosion induced by the compressive stress between them [81]. In China, Wu et al [82] observed firstly the crevice corrosion morphology of the screw head without contact with the plate was different from the contact regions in the screw between the screw and the plate on the bone of rat.…”
Section: Discussionmentioning
confidence: 99%