2016
DOI: 10.2109/jcersj2.15246
|View full text |Cite
|
Sign up to set email alerts
|

Influence of temperature and humidity on the electrical sensing of Pt/WO<sub>3</sub> thin film hydrogen gas sensor

Abstract: Platinum catalyst loaded tungsten oxide (Pt/WO 3 ) is a promising candidate as a hydrogen gas sensor material, which can detect it through optical and electrical sensing. The sensor, which can detect the hydrogen gas stably in various environments, is strongly demanded. In this study, we prepared the Pt/WO 3 thin film by the solgel method and evaluate the dependence of the hydrogen gas sensing property on measuring temperature and humidity. Hydrogen gas sensing property of Pt/WO 3 thin film was evaluated by me… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
6
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 17 publications
(7 citation statements)
references
References 16 publications
1
6
0
Order By: Relevance
“…Therefore, they are expected to be resistant to aging degradations. The effect of humidity on Pt/WO 3 coloration was verified in a previous study [ 22 ]. In this study, PDMS is a hydrophobic polymer, which prevents water from diffusing into the membrane, and the effect of humidity is considered to be small.…”
Section: Resultssupporting
confidence: 60%
“…Therefore, they are expected to be resistant to aging degradations. The effect of humidity on Pt/WO 3 coloration was verified in a previous study [ 22 ]. In this study, PDMS is a hydrophobic polymer, which prevents water from diffusing into the membrane, and the effect of humidity is considered to be small.…”
Section: Resultssupporting
confidence: 60%
“…At 150 • C, the sensitivity is partially reduced (~3.4), but the response is the same regardless of humidity (Figure 9c). This can be explained by the fact that the OH groups on the surface desorb at higher temperatures, which can partly eliminate the humidity effect [53,54]. At these conditions, the minimum detectable concentration of hydrogen was 500 ppm.…”
Section: Sensing Responsementioning
confidence: 99%
“…There is a lot of published data in the literature measuring sensor response time in high humidity environments. A typical example is featured in Yamaguchi's work [33]. In general, the sensing property declined in humid atmospheres because water molecules adsorbing on the film surface disturbed the catalytic reaction between hydrogen and Pt.…”
Section: Fabrication Of Prototype and Characterization Of Its Electrimentioning
confidence: 99%