2015
DOI: 10.1016/j.enconman.2015.01.090
|View full text |Cite
|
Sign up to set email alerts
|

Influence of the desiccant wheel effectiveness method approaches, with fix and variable effectiveness parameters, on the performance results of an airport air-conditioning system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 27 publications
0
9
0
Order By: Relevance
“…In a simulation of a VAV air conditioning system, using the frequency response method, Yao and Wang [41] have assumed the indoor air temperature to be kept constant throughout the year. Conversely, Ruivo et al [42] in simulations, with TRNSYS, of a VAV air conditioning system of an airport terminal, assumed two constant values of indoor air temperatures in agreement with the cooling and heating operating modes. Different control strategies of the air conditioning system were taken into account in the system simulations addressed in the work of Ruivo and co-workers.…”
Section: Final Remarksmentioning
confidence: 96%
See 1 more Smart Citation
“…In a simulation of a VAV air conditioning system, using the frequency response method, Yao and Wang [41] have assumed the indoor air temperature to be kept constant throughout the year. Conversely, Ruivo et al [42] in simulations, with TRNSYS, of a VAV air conditioning system of an airport terminal, assumed two constant values of indoor air temperatures in agreement with the cooling and heating operating modes. Different control strategies of the air conditioning system were taken into account in the system simulations addressed in the work of Ruivo and co-workers.…”
Section: Final Remarksmentioning
confidence: 96%
“…In what regards the application of the innovative approach to the case investigated by Ruivo et al [42], it would be important to evaluate the error of the thermal loads predicted during the period of two or three days after the changeover between heating and cooling modes.…”
Section: Final Remarksmentioning
confidence: 99%
“…As future work, investigation into the optimization of the desiccant system and the improvement of dehumidification/humidification performance by numerical analysis [11,18] will be accomplished.…”
Section: Discussionmentioning
confidence: 99%
“…This has been reported as an effective method for reducing the degradation of the Indoor Air Quality (IAQ), which is caused by microbes, such as mold or bacteria [1][2][3][4]. In addition, many studies have been conducted on the application of desiccant air-conditioning systems as dedicated outdoor air systems (DOASs) during the summer [5][6][7][8][9][10][11][12][13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%
“…Different models of the desiccant wheel have been developed by many researchers over the years [30][31][32]. In this work, the operation of the desiccant wheel is simulated using the Type 1716 (component of the TESS library), containing a model based on the equations for F1 and F2 potentials developed by Jurinak [33]:…”
Section: Desiccant Wheel Modelmentioning
confidence: 99%