Influence of the distal femoral resection angle on the principal stresses in ceramic total knee components

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 17 publications
0
6
0
Order By: Relevance
“…New trends are found in the application of large femoral heads for enhanced range of motion and dislocation stability as well as in the application of ceramics in revision tha (Pandorf, 2007). With substantial improvements in the mechanical properties, ceramic components for total knee replacement have been reintroduced (mittelmeier et al, 2006;Bergschmidt et al, 2012). hence, improved long-term implant survival rates based on the high corrosion resistance and reduced release of polyethylene wear particles can be expected in tKa in the near future.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…New trends are found in the application of large femoral heads for enhanced range of motion and dislocation stability as well as in the application of ceramics in revision tha (Pandorf, 2007). With substantial improvements in the mechanical properties, ceramic components for total knee replacement have been reintroduced (mittelmeier et al, 2006;Bergschmidt et al, 2012). hence, improved long-term implant survival rates based on the high corrosion resistance and reduced release of polyethylene wear particles can be expected in tKa in the near future.…”
Section: Resultsmentioning
confidence: 99%
“…The clinical evaluation showed significant improvements in all scores from the pre-operative to the post-operative evaluations (Bergschmidt et al, 2012).…”
Section: 3mentioning
confidence: 89%
See 1 more Smart Citation
“…11 Ceramic femoral components can be used, 23,24 but these implants are expensive, and their application is more demanding. 25,26 Therefore, in most patients with a metal hypersensitivity, coated standard implants are used. In addition to demonstrating reduction of metal ion release, these coatings demonstrated superior abrasive properties and reduction of polyethylene wear.…”
Section: Discussionmentioning
confidence: 99%
“…stemmed or stemless) can exert a large influence on the global motions between bone and implant [20][21][22][23]. Recent studies have suggested that implant design features such as size and placement of distal femoral pegs [24], anterioposterior slope of the femoral component [25], and angle of fit of the implant [26], may also play a role in the long term survival of the prosthesis.…”
Section: Introductionmentioning
confidence: 99%