2020
DOI: 10.1049/iet-smt.2019.0558
|View full text |Cite
|
Sign up to set email alerts
|

Influencing of water droplets on corona inception characteristics of composite insulator recorded by UV imager

Abstract: Water droplets on the surface of insulators can distort the electric field and cause the generation of surface partial discharge or flashover. In this study, the inception and the development of surface partial discharges on a 110 kV composite insulator were evaluated by using a solar-blind ultraviolet imager. Several experiments were conducted by using water droplets differing in volume, conductivity, and position on an insulator housing. The results showed that the corona inception voltage decreases with the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 23 publications
0
2
0
Order By: Relevance
“…In this study, the light spot area is defined as the number of white pixels in the image after spot recognition, measured in pixels. By applying Equation (7), the number of white pixels in the image can be counted to obtain the area of the corona discharge light spot. In the equation, M and N represent the rows and columns of the processed RGB image matrix, respectively.…”
Section: Calculation Of Discharge Area Parameters In Ultraviolet Dete...mentioning
confidence: 99%
See 1 more Smart Citation
“…In this study, the light spot area is defined as the number of white pixels in the image after spot recognition, measured in pixels. By applying Equation (7), the number of white pixels in the image can be counted to obtain the area of the corona discharge light spot. In the equation, M and N represent the rows and columns of the processed RGB image matrix, respectively.…”
Section: Calculation Of Discharge Area Parameters In Ultraviolet Dete...mentioning
confidence: 99%
“…The detection of corona-related defects in transmission lines has been included in the scope of defect detection work for transmission lines. In recent years, ultraviolet (UV) detection technology has been widely applied for the accurate, fast, visual, and safe detection of corona discharges in electrical equipment [4][5][6][7][8][9]. Some relevant studies [10][11][12][13] have been conducted on the corona inception voltage of conductors using ultraviolet detection technology.…”
Section: Introductionmentioning
confidence: 99%