2019
DOI: 10.1109/access.2019.2912525
|View full text |Cite
|
Sign up to set email alerts
|

Influential Factors and Correction Method of Furfural Content in Transformer Oil

Abstract: Furfural content in transformer oil is considered a credible method to evaluate the aging extent of insulation paper and is extensively applied to the aging assessment of insulation system in transformers. Clearly, the accuracy of furfural analysis is directly related to the stability of furfural in oil, which, nevertheless, may be affected by various factors. In this research, furfural was added to insulation oil directly to analyze its stability in oil firstly. Furfural contents in different conditions, such… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 20 publications
(20 reference statements)
0
3
0
Order By: Relevance
“…For this reason, there is an attempt to determine the DP value via the determination of aging markers in the insulating liquid, such as with the measurement of the furan concentration, whereby the DP value of the paper is indirectly inferred via algorithms [14][15][16]. However, fluctuations in furan concentration may occur during operation [17,18]. Furthermore, this is also influenced by the type of insulating liquid, which can affect the accuracy of the DP value calculation [19].…”
Section: Introductionmentioning
confidence: 99%
“…For this reason, there is an attempt to determine the DP value via the determination of aging markers in the insulating liquid, such as with the measurement of the furan concentration, whereby the DP value of the paper is indirectly inferred via algorithms [14][15][16]. However, fluctuations in furan concentration may occur during operation [17,18]. Furthermore, this is also influenced by the type of insulating liquid, which can affect the accuracy of the DP value calculation [19].…”
Section: Introductionmentioning
confidence: 99%
“…Among all the above‐mentioned methods, furfural analysis is regarded as an effective evaluation method because furfural is peculiar to the ageing process of insulation paper. Considering that the insulation paper is difficult to be repaired or replaced in the whole lifespan, it is the weak point of oil‐paper insulation and determines the insulation life [12, 13]. Plenty of studies have been conducted on the transformers' ageing assessment with furfural content in oil in recent years.…”
Section: Introductionmentioning
confidence: 99%
“…To date, lots of methods are proposed for the ageing assessment of transformers, including dissolved gas analysis, furfural analysis, frequency-domain spectroscopy, and so on, which are a benefit to perceiving the states of transformers [8][9][10][11].Among all the above-mentioned methods, furfural analysis is regarded as an effective evaluation method because furfural is peculiar to the ageing process of insulation paper. Considering that the insulation paper is difficult to be repaired or replaced in the whole lifespan, it is the weak point of oil-paper insulation and determines the insulation life [12,13]. Plenty of This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.…”
mentioning
confidence: 99%