2011
DOI: 10.1148/rg.313105125
|View full text |Cite
|
Sign up to set email alerts
|

Informatics in Radiology: Use of a C-Arm Fluoroscopy Simulator to Support Training in Intraoperative Radiography

Abstract: Mobile image intensifier systems (C-arms) are used frequently in orthopedic and reconstructive surgery, especially in trauma and emergency settings, but image quality and radiation exposure levels may vary widely, depending on the extent of the C-arm operator's knowledge and experience. Current training programs consist mainly of theoretical instruction in C-arm operation, the physical foundations of radiography, and radiation avoidance, and are largely lacking in hands-on application. A computer-based simulat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
18
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(18 citation statements)
references
References 18 publications
0
18
0
Order By: Relevance
“…Fluoroscopy simulation methods that have been previously proposed relied upon external tracking systems to align the patient position relative to the C-arm imaging coordinate system and were primarily intended for surgical training purposes [1], [2]. Considering the task of C-arm positioning, the use and adaptation of external tracking systems are challenging due to the line-of-sight requirements and the addition of cumbersome hardware equipment in the operating rooms.…”
Section: Introductionmentioning
confidence: 99%
“…Fluoroscopy simulation methods that have been previously proposed relied upon external tracking systems to align the patient position relative to the C-arm imaging coordinate system and were primarily intended for surgical training purposes [1], [2]. Considering the task of C-arm positioning, the use and adaptation of external tracking systems are challenging due to the line-of-sight requirements and the addition of cumbersome hardware equipment in the operating rooms.…”
Section: Introductionmentioning
confidence: 99%
“…This is even more of a concern in the pediatric population, with clinicians encouraged to make judicious use of x-ray and CT imaging. 6,7 In procedures utilizing intraoperative x-ray imaging, simulation has been shown to be an effective tool for improving the trainee's understanding of the principles of image acquisition and radiation exposure, 8 and in reducing radiation exposure while improving performance in clinical care. We have developed a simulator for training clinicians to perform x-ray fluoroscopy based diagnosis.…”
Section: Introductionmentioning
confidence: 99%
“…Accurate positioning technique of mobile C-arm is required in surgical applications, for example, percutaneous needle procedures and fracture fixation with locking screws and nails. In such cases, the C-arm needs to be piloted to the needle progression view and entry point view to confirm the current pose of the needle [2] or over the nail so that each screw hole appears as a perfect circle [3]. Therefore, mobile C-arm positioning is a routine surgical task and has become more important for the intraoperative imaging techniques [4].…”
Section: Introductionmentioning
confidence: 99%