1988
DOI: 10.1021/ac00169a028
|View full text |Cite
|
Sign up to set email alerts
|

Infrared-enhanced multiphoton ionization detection of aromatic molecules in solution

Abstract: the ringer solution. These interferences include peaks B and F, and the negative deflections found at ca. 5.1, 7-7, 8.2, and 13 min. Schemes are being developed to eliminate these interferences. Peaks A, C, D, E, and G appear to be "real" peaks. Peak G is presumably an anionic compound, possibly a metabolite of dopamine, and has been seen in larger quantities in other samples. Future work will involve determination of the identity of solutes detected in these experiments. ACKNOWLEDGMENTThe authors wish to than… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
8
0

Year Published

1989
1989
2011
2011

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 32 publications
(9 citation statements)
references
References 35 publications
1
8
0
Order By: Relevance
“…The slope of the logarithmic plots of PC(355) or PC(355 + 1064) versus the concentration was nearly unity in the 10"10 to 1CT7 M region. Below about 10~9 M, APC/ PC(355) tended to be constant; PC(355 + 1064) was 6-7-fold larger than PC(355), as was the case in the previous result (18).…”
Section: Resultssupporting
confidence: 76%
See 2 more Smart Citations
“…The slope of the logarithmic plots of PC(355) or PC(355 + 1064) versus the concentration was nearly unity in the 10"10 to 1CT7 M region. Below about 10~9 M, APC/ PC(355) tended to be constant; PC(355 + 1064) was 6-7-fold larger than PC(355), as was the case in the previous result (18).…”
Section: Resultssupporting
confidence: 76%
“…The UV (355 nm) and IR (1064 nm) two-color laser photoionization detection system is almost identical with the previous one (18). A Nd:YAG laser (Quantel YG 580A, pulse duration 10 ns) was operated at a repetition rate of 5 Hz.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Interfadal Electrochem. Laser multiphoton ionization spectrometry based on photocurrent measurement is sensitive for the determination of organic molecules in solution (1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13). The detection sensitivity in this method depends on laser power (9)(10)(11)(12)(13), excitation wavelength (8,9), molar absorptivity of an analyte (4, 7-9), and the polarity of a solvent (3,7).…”
mentioning
confidence: 99%
“…From these viewpoints, we have attempted to increase the yield of free ion pairs generated from geminate ion pairs by irradiating the geminate ion pairs with the near-infrared laser light synchronized with the ultraviolet laser light. 24,25 The results for 9-phenylanthracene dissolved in heptane are presented in Fig. 4(b).…”
Section: ·3 Two-color Multiphoton Ionization Detectionmentioning
confidence: 99%