2003
DOI: 10.1088/0022-3727/36/13/314
|View full text |Cite
|
Sign up to set email alerts
|

Infrared losses from a Na/Sc metal-halide high intensity discharge arc lamp

Abstract: A study of the near-infrared (IR) emission from the arc of a metal-halide high intensity discharge (MH-HID) lamp with a sodium/scandium chemistry is reported. Radiometrically calibrated spectra from 0.7 to 2.5 μm were recorded as a function of position on the arc tube of a 250 W lamp. These spectra were analysed to determine the relative densities of Na and Sc atoms and the arc temperature as a function of radius. Information from these spectra, combined with absorption measurements in the companion paper (Bon… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
10
0

Year Published

2003
2003
2011
2011

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 12 publications
0
10
0
Order By: Relevance
“…Published measurements of near-IR losses in 400 W metal-halide lamps range from more than 25% of input power to less than 10% [1][2][3]. It is not clear whether this wide range of values is primarily the result of the different chemistries or of measurement errors.…”
Section: Introductionmentioning
confidence: 99%
“…Published measurements of near-IR losses in 400 W metal-halide lamps range from more than 25% of input power to less than 10% [1][2][3]. It is not clear whether this wide range of values is primarily the result of the different chemistries or of measurement errors.…”
Section: Introductionmentioning
confidence: 99%
“…The arc tubes were vertically oriented during measurements to replicate commercial operation. Three different arc tubes were used in the course of this investigation, and two of these were also used in the IR emission studies described in the companion paper (Smith et al 2003).…”
Section: Mh-hid Lamp Chamber and Ballastmentioning
confidence: 99%
“…One of the major goals of the research described in this paper and the companion paper (Smith et al 2003) is to explore the infrared (IR) losses of MH-HID lamps.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Infrared radiation, either in the form of radiation from the plasma or in the form of thermal radiation from the burner wall, can consume 50-75% of the total input power. The ALITE-II project's [6] primary focus was the infrared radiation of HID lamps; several papers regarding the infrared radiation from HID lamps have recently been published [7][8][9]. In these papers the focus was mainly on the continuum radiation generated by the plasma.…”
Section: Introductionmentioning
confidence: 99%