2017
DOI: 10.1016/j.cej.2017.05.001
|View full text |Cite
|
Sign up to set email alerts
|

Infrared thermo-spectroscopic imaging of styrene radical polymerization in microfluidics

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
18
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 31 publications
(18 citation statements)
references
References 32 publications
0
18
0
Order By: Relevance
“…The thermal digital signal can be translated to temperature of a certain area of the sample if the relationships among concentration, temperature, and IR emisssion are determined beforehand. This requires calibration for concentration vs thermal signal and temperature vs thermal signal on the sample examined, as discussed by Ryu et al . Nonetheless, subjecting biological specimens to heating can result in irreversible cellular and structural changes , thus the calibration is avoided in this case.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The thermal digital signal can be translated to temperature of a certain area of the sample if the relationships among concentration, temperature, and IR emisssion are determined beforehand. This requires calibration for concentration vs thermal signal and temperature vs thermal signal on the sample examined, as discussed by Ryu et al . Nonetheless, subjecting biological specimens to heating can result in irreversible cellular and structural changes , thus the calibration is avoided in this case.…”
Section: Resultsmentioning
confidence: 99%
“…The input trigger of the camera is highly synchronised with the signal to the chopper to achieve high simultaneity in measurement with the in‐house written LabView software (Tokyo Institute of Technology, Tokyo, Japan). A schematic of the optical setup is shown by Ryu et al .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this study, the co-flow interface between water and ethanol, water and HCl solution, and styrene radical polymerization were chosen for the example of two components system, and the neutralization reaction of acid and base was chosen for the three components concentration distributed system of HCl, NaOH, and NaCl solution. The conventional micro-scale thermos-spectroscopic imaging set up for microfluidics chip [3] was used for the experiment and E image were obtained from the thermal emission image of the set up and C image were obtained from spectroscopic image of the system. For the phase transition, solid-rotator-liquid transition of n -tetracosane (C24H50, C24) was chosen for the investigation.…”
Section: Methodsmentioning
confidence: 99%
“…Such systems require integration with micromixers to mix reagent molecules, fluids or species for chemical reactions [1], which emphasizes on the significance of mixing in micro-scale. The applications of micromixing cover a variety of fields, including biomedical systems [2], sample concentration [3], chemical synthesis [4], chemical reactors [5], polymerization [6], extraction [7], DNA purification [8], biological analysis processes [9], droplet [10] and emulsion [11] processes. The growing demand for micromixers in such fields necessitates the understanding of the involved mechanisms in order to improve their design for effective mixing.…”
Section: Introductionmentioning
confidence: 99%