Inhaled salbutamol dose delivered by jet nebulizer, vibrating mesh nebulizer and metered dose inhaler with spacer during invasive mechanical ventilation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
42
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 47 publications
(42 citation statements)
references
References 34 publications
0
42
0
Order By: Relevance
“…The volume of 30-min and 24-h collection samples were measured and assayed for salbutamol using previously validated high-performance liquid chromatography. 14,15,17,21,31 Salbutamol was extracted from urine samples using solid-phase extraction with Oasis MCX cartridge (Waters Corporation, Milford, Massachusetts), with bambuterol hydrochloride added as internal standard, and then injected into the high-performance liquid chromatography system. A 5-m octadecyl-silica (ODS) (4.6 mm ϫ 250 mm, Zorbax Eclipse) C-18 high-performance liquid chromatography column with a 4 mm ϫ 3 mm C-18 (ODS) guard column (Agilent, Santa Clara, California) was used.…”
Section: With and Without Humidificationmentioning
confidence: 99%
“…The volume of 30-min and 24-h collection samples were measured and assayed for salbutamol using previously validated high-performance liquid chromatography. 14,15,17,21,31 Salbutamol was extracted from urine samples using solid-phase extraction with Oasis MCX cartridge (Waters Corporation, Milford, Massachusetts), with bambuterol hydrochloride added as internal standard, and then injected into the high-performance liquid chromatography system. A 5-m octadecyl-silica (ODS) (4.6 mm ϫ 250 mm, Zorbax Eclipse) C-18 high-performance liquid chromatography column with a 4 mm ϫ 3 mm C-18 (ODS) guard column (Agilent, Santa Clara, California) was used.…”
Section: With and Without Humidificationmentioning
confidence: 99%
“…The choice of inhaled salbutamol dosage was in accordance with previous literature. 16,18,[24][25][26][27][28][29][30][31][32][33][34][35][36] As recommended previously in studies that used single-limb NIV, 10,30 the nebulizers were placed proximal to the subject and distal to the fixed expiratory valve, as shown in Figure 1.…”
Section: Study Protocolmentioning
confidence: 99%
“…The findings will help in developing policy and best practice for risk mitigation from fugitive emissions.Aerosol generation technologies deliver drugs to the lungs of neonatal, paediatric and adult patients through a variety of patient interfaces. Several factors influence aerosol drug delivery to the lungs, including the aerosol-generating device, the size distribution of the inhaled aerosol, the gas-flow rate, the inhalation pattern and the type of interface [5][6][7][8][9].Dysart et al [10] reported that the use of high-flow nasal therapy (HFNT) devices is rapidly growing in the clinical setting, for different age groups with a range of disease conditions. High-flow nasal therapy studies have reported gas-flow rates of 3 to 20 L/min for paediatrics, and 5 to 60 L/min for adults [11][12][13][14].…”
mentioning
confidence: 99%
“…Aerosol generation technologies deliver drugs to the lungs of neonatal, paediatric and adult patients through a variety of patient interfaces. Several factors influence aerosol drug delivery to the lungs, including the aerosol-generating device, the size distribution of the inhaled aerosol, the gas-flow rate, the inhalation pattern and the type of interface [5][6][7][8][9].…”
mentioning
confidence: 99%