“…Filamented borosilicate capillary tubes were pulled and fire-polished to a resistance of ~5 MΩ for recording from cell lines and ~10 MΩ for recording from primary cells. The extracellular physiological saline solution (PSS) contained (in mM) NaCl 144, KCl 5.4, MgCl 2 1, CaCl 2 2.5, HEPES 5, D-glucose 5.6, and was adjusted to pH 7.2 (unless otherwise stated) using NaOH.The intracellular recording solution for measuring Na + currents contained (in mM) NaCl 5, CsCl 145, MgCl 2 2, CaCl 2 1, HEPES 10, EGTA 11 and was adjusted to pH 7.4 (unless otherwise stated) using CsOH(29). The intracellular recording solution for measuring K + currents contained (in mM) NaCl 5, KCl 145, MgCl 2 2, CaCl 2 1, HEPES 10, EGTA 11 and was adjusted to pH 7.4 using KOH.…”