2008
DOI: 10.1016/j.hrthm.2008.08.024
|View full text |Cite
|
Sign up to set email alerts
|

Initial experience with the Mesh catheter for pulmonary vein isolation in patients with paroxysmal atrial fibrillation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
23
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 39 publications
(25 citation statements)
references
References 21 publications
2
23
0
Order By: Relevance
“…From a historical standpoint, the first catheter using a circumferential multielectrode approach for sensing and simultaneous ablation with the same electrodes was the Mesh ablator. 710 However, due to technical limitations of the system and poor clinical outcome, this system is no longer available. The nMARQ catheter is a combined decapolar irrigated ablation and mapping RF system.…”
Section: Section 6: Technology and Toolsmentioning
confidence: 99%
“…From a historical standpoint, the first catheter using a circumferential multielectrode approach for sensing and simultaneous ablation with the same electrodes was the Mesh ablator. 710 However, due to technical limitations of the system and poor clinical outcome, this system is no longer available. The nMARQ catheter is a combined decapolar irrigated ablation and mapping RF system.…”
Section: Section 6: Technology and Toolsmentioning
confidence: 99%
“…Using the high density mesh ablation (HDMA) catheter, Mansour et al [5] showed efficacy in electrical isolation of 63% of the PVs and 40% of the patients after a mean of 12 min of ablation time for each vein. Data concerning the cryoballoon showed that successful isolation of the PVs was possible in up to 92.5% of the veins and 83% of the patients [6].…”
Section: Procedures Performance Of the Pvacmentioning
confidence: 99%
“…The only other single-shot device which combines diagnostic and therapeutic tools is the HDMA catheter. Mansour et al [5] presented that 12% of the veins which seemed isolated on the HDMA, were not isolated on a regular circular mapping catheter. The other study showed that PVAC has a diagnostic accuracy of 95% [8].…”
Section: Procedures Performance Of the Pvacmentioning
confidence: 99%
“…Th e clinical performance of the MESH for mapping before ablation, the ablation itself, and after delivery of the RF current has been demonstrated previously [19,20].…”
Section: Original Articlementioning
confidence: 99%