2009
DOI: 10.1016/j.clinimag.2008.12.007
|View full text |Cite
|
Sign up to set email alerts
|

Initial experience with visualizing hand and foot tendons by dual-energy computed tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
23
0

Year Published

2010
2010
2015
2015

Publication Types

Select...
8
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 43 publications
(23 citation statements)
references
References 12 publications
0
23
0
Order By: Relevance
“…When patients with knee trauma underwent CT scans, VNCa technique of DECT with appropriately reduced radiation dose can be routinely applied to detect traumatic BMLs, which was affirmed in a previous study with a reduced volume CT dose index of 8.69 mGy for DECT protocol [24]. In addition to VNCa images, DECT tendon imaging can also be used to observe tendons and ligaments of the knee joint [17,[25][26][27][28], because DECT technology is able to identify dense hydroxylysine and hydroxyproline residues in the side chains of the collagen structure of tendons and ligaments. In addition, CT images are superior to show fracture details.…”
Section: Discussionmentioning
confidence: 83%
“…When patients with knee trauma underwent CT scans, VNCa technique of DECT with appropriately reduced radiation dose can be routinely applied to detect traumatic BMLs, which was affirmed in a previous study with a reduced volume CT dose index of 8.69 mGy for DECT protocol [24]. In addition to VNCa images, DECT tendon imaging can also be used to observe tendons and ligaments of the knee joint [17,[25][26][27][28], because DECT technology is able to identify dense hydroxylysine and hydroxyproline residues in the side chains of the collagen structure of tendons and ligaments. In addition, CT images are superior to show fracture details.…”
Section: Discussionmentioning
confidence: 83%
“…Tendon and ligament visualization has been proposed by CT vendors, but few studies have evaluated this application ( Fig. 13) (123)(124)(125). CT artrography using the dual-energy technique has also been described (126).…”
Section: Musculoskeletal Applicationsmentioning
confidence: 99%
“…12 Collagen material decomposition algorithms have been created to depict tendons and ligaments, 8 and this has included detection of pathology. 13 Dual-energy CT scan SOMATOM Definition Flash (Siemens Healthcare) has 2 x-ray tubes/detector pairs, housed at 90 degrees to one another in the gantry. These rotate simultaneously at different energy levels (typically at approximately 100 and 140 kV) acquiring 2 data sets.…”
mentioning
confidence: 99%