Global Solutions for Urban Drainage 2002
DOI: 10.1061/40644(2002)276
|View full text |Cite
|
Sign up to set email alerts
|

Inlet Spacing Considering the Risk Associated to Runoff. Application to Streets and Critical Points of the City of Barcelona

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 0 publications
0
5
0
Order By: Relevance
“…If the maximum flow depth is limited to 3 cm, then the limitations are inescapable and become a major restriction to spacing consideration (Figure 5), which is consistent with the conclusion of Wong and Moh [19], who found exponential increase in inlet spacing with increasing maximum spacing. (This means decreasing maximum flow depths (as Gomez et al [20] suggest) or the spread results in drastic variations).…”
Section: Discussionmentioning
confidence: 92%
See 1 more Smart Citation
“…If the maximum flow depth is limited to 3 cm, then the limitations are inescapable and become a major restriction to spacing consideration (Figure 5), which is consistent with the conclusion of Wong and Moh [19], who found exponential increase in inlet spacing with increasing maximum spacing. (This means decreasing maximum flow depths (as Gomez et al [20] suggest) or the spread results in drastic variations).…”
Section: Discussionmentioning
confidence: 92%
“…Wong and Moh [19] analyzes spacing (dismissing hydroplaning), also using fixed spread for the inlets used in Singapore. Gomez et al [20], however, limit the maximum flow depth at the curb to 3 cm, stating that it is the "sole thickness of a normal shoe"; the 3 cm limit is also what Moftakhari et al [21] set as the start of nuisances that are considered to disrupt daily routines. HEC-22, the urban drainage design manual of US Department of Transportation, provides guidance for locating inlets, starting from the ones that must be prioritized based on geometric control (e.g., at sags and pedestrian crosswalks).…”
Section: Introductionmentioning
confidence: 99%
“…Both grates, along with grate 3, were used for the numerical simulation in Flow 3D. Grates were examined previously in [14,15,52], and grate 2 was tested during the period of internship of Amezaga-Kutija [53].…”
Section: Experimental Set-upmentioning
confidence: 99%
“…Both grates, along with grate 3, were used for the numerical simulation in Flow 201 3D. Grates were examined previously in [14,15,52], and grate 2 was tested during the pe-202 riod of internship of Amezaga-Kutija [53]. with a width of 3 m and a total length of 5.5 m, where a single inlet can be tested (Figure 1).…”
Section: Experimental Set-upmentioning
confidence: 99%
See 1 more Smart Citation