Hybrid Cardiac Imaging 2021
DOI: 10.1007/978-3-030-83167-7_14
|View full text |Cite
|
Sign up to set email alerts
|

Innovations in Cardiovascular MR and PET-MR Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 159 publications
0
3
0
Order By: Relevance
“…Additionally, PET‐MR imaging has shown promise for enhanced characterization of cardiovascular disease. Motion correction of PET data using MR has demonstrated to improve the PET images 43,44 . One of the approaches was proposed by Kolbitsch et al, 45 where PET data were corrected using single contrast MRI making cardiac PET results more reproducible.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Additionally, PET‐MR imaging has shown promise for enhanced characterization of cardiovascular disease. Motion correction of PET data using MR has demonstrated to improve the PET images 43,44 . One of the approaches was proposed by Kolbitsch et al, 45 where PET data were corrected using single contrast MRI making cardiac PET results more reproducible.…”
Section: Discussionmentioning
confidence: 99%
“…Motion correction of PET data using MR has demonstrated to improve the PET images. 43,44 One of the approaches was proposed by Kolbitsch et al, 45 where PET data were corrected using single contrast MRI making cardiac PET results more reproducible. In our work, T 2 mapping adds diagnostic value to the simultaneous PET-MR acquisition, which is especially useful in patients with inflammatory diseases like cardiac sarcoidosis.…”
Section: F I G U R Ementioning
confidence: 99%
“…By acquiring MR images that can provide respiratory and cardiac motion information, the simultaneously acquired PET data can be corrected for motion, resulting in improved delineation and quantification for cardiac PET images. A review of these techniques can be found in (51). While most of these techniques have focused on myocardial viability imaging with 18 F-FDG PET, the study by Robson et al (52) studied the potential of MR-based cardiac and respiratory motion correction in patients with CS, demonstrating that this approach resulted in improved visual appearance of the 18 F-FDG uptake pattern in areas of the heart most affected by motion, and in increased contrast of the detected lesions.…”
Section: Opportunities and Challengesmentioning