Innovative Adaptive Protection Approach to Maximize the Security and Performance of Phase/Earth Overcurrent Relay for Microgrid Considering Earth Fault Scenarios.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 32 publications
(21 citation statements)
references
References 28 publications
0
21
0
Order By: Relevance
“…The increasing of DGs in the distribution networks make the OC relays coordination an increasingly complex problem. Recently, various researchers have presented the nonstandard curve characteristics as a potential solution for the protection coordination problem in microgrid [17], [18] and using the metaheuristic optimization algorithms [19]. In [12] and [20], the OC coordination problem described as objective function with several constraints and they used the GA method to achieve the minimum operation time for the relays by finding the optimal settings for the OC relays.…”
Section: B Literature Reviewmentioning
confidence: 99%
See 4 more Smart Citations
“…The increasing of DGs in the distribution networks make the OC relays coordination an increasingly complex problem. Recently, various researchers have presented the nonstandard curve characteristics as a potential solution for the protection coordination problem in microgrid [17], [18] and using the metaheuristic optimization algorithms [19]. In [12] and [20], the OC coordination problem described as objective function with several constraints and they used the GA method to achieve the minimum operation time for the relays by finding the optimal settings for the OC relays.…”
Section: B Literature Reviewmentioning
confidence: 99%
“…Therefore, the Plug Setting Multiplier (PSM) is selected within the maximum and minimum limitations based on the fault current level seen by the relay (maximum and minimum) and the load level as light load or overload. In general, the PSM limits start from 1.1 to 20 times of PSM for OC relays in industrial and microgrid applications [4], [7], [19]. In this paper, the PSM limits vary between 1.1 and 100, where the PMS has been extended to 100 instead of 20 times of PSM to cover the different increases in the DGs and fault current levels in the microgrid.…”
Section: • Coordination Problem: Objective Function and Constraintsmentioning
confidence: 99%
See 3 more Smart Citations