Abstract-Minimally Invasive Vitrectomy System is a concept that was developed during the past years with the goal to make pars plana vitrectomy a safer and a less traumatizing procedure. The development of small gauge vitrectomy systems has led to the decrease of tissue damage and the shortening of the operating time. Although MIVS is increasingly popular, its use varies substantially according to the personal experience of each vitreo-retinal surgeon. The transition from the 20 gauge to the small gauge vitrectomy (23G, 25G) is directly related to the global approach to vitrectomy regarding incision making, intraoperative fluidics, cutting technology, illumination and accessory instruments. The development of new instruments capable to overcome the size and lumen handicaps became necessary. The use of small gauge instruments has various consequences on the vitrectomy itself: the modification of fluidics during surgery, the decrease of illumination, the need of fewer accessory and multi-function instruments.For the past 12 months, we used 25+ vitrectomy system sustained by the Constellation platform, in 296 cases that required vitreo-retinal surgery. The clinical conditions were the following ones: rhegmatogenous retinal detachments (120 cases -40.54%), vitreous haemorrhages (100 cases -33.78%), tractional retinal detachments (35 cases -11.82%), epimacular membranes (15 cases -5.06%), nucleus/lens luxated into the vitreous cavity (11 cases -3.71%), intraocular foreign bodies (6 cases -2.02%), macular holes (5 cases -1.68%), endophthalmitis (4 cases -1.35%).In this paper, the personal experience of using MIVS in variate cases that required vitreo-retinal surgery is illustrated.
Abstract-Minimally Invasive Vitrectomy System is a concept that was developed during the past years with the goal to make pars plana vitrectomy a safer and a less traumatizing procedure. The development of small gauge vitrectomy systems has led to the decrease of tissue damage and the shortening of the operating time. Although MIVS is increasingly popular, its use varies substantially according to the personal experience of each vitreo-retinal surgeon. The transition from the 20 gauge to the small gauge vitrectomy (23G, 25G) is directly related to the global approach to vitrectomy regarding incision making, intraoperative fluidics, cutting technology, illumination and accessory instruments. The development of new instruments capable to overcome the size and lumen handicaps became necessary. The use of small gauge instruments has various consequences on the vitrectomy itself: the modification of fluidics during surgery, the decrease of illumination, the need of fewer accessory and multi-function instruments.For the past 12 months, we used 25+ vitrectomy system sustained by the Constellation platform, in 296 cases that required vitreo-retinal surgery. The clinical conditions were the following ones: rhegmatogenous retinal detachments (120 cases -40.54%), vitreous haemorrhages (100 cases -33.78%), tractional retinal detachments (35 cases -11.82%), epimacular membranes (15 cases -5.06%), nucleus/lens luxated into the vitreous cavity (11 cases -3.71%), intraocular foreign bodies (6 cases -2.02%), macular holes (5 cases -1.68%), endophthalmitis (4 cases -1.35%).In this paper, the personal experience of using MIVS in variate cases that required vitreo-retinal surgery is illustrated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.