Archimedes Spiral Turbine has characteristic of blade which can catch water flow well. It uses two force concepts, i.e. drag and lift forces. Flow direction change greatly influences Archimedes Spiral turbine performance. Therefore, it needs flow direction system in form of truncated cone and tail vane. Archimedes Spiral turbine with flow direction system generated Cp value of 0,19–0,22 and TSR value between 1,76–1,85. Torque value obtained is between 0,013–0,017 Nm on RPM value range of 28,64–33,60. Limitation between truncated cone with Archimedes Spiral turbine blade causes vortex flow at the back of blade to decrease. Truncated cone addition can enlarge flow catchment force. When flow speed captured by Archimedes Spiral turbine increase, resulting in a compressive force on enlarged. The addition of tail vane capable of passing the flow vortex is elongated to downstream. The flow of vortex which is passed on inhibits the rotation of the turbine blades and result in a compressive force on the turbine is enlarged. Compressive force on blade which grows bigger causes torque value to increase as well. The increasing torque value causes drag force concept used in Archimedes Spiral turbine with flow direction system higher than lift force concept.