2021
DOI: 10.1016/j.ocl.2021.03.001
|View full text |Cite
|
Sign up to set email alerts
|

Instability After Total Hip Arthroplasty and the Role of Advanced and Robotic Technology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 98 publications
0
5
0
Order By: Relevance
“…The success of traditional THA depends largely on the precision of implant placement, which requires extensive surgical experience [ 3 ]. Furthermore, with the widespread adoption of THA, the number of patients requiring hip revision due to dislocations, impingement, pelvic osteolysis, acetabular displacement, polyethylene wear, and unequal leg length is increasing, seriously affecting patient satisfaction and quality of life [ 4 ]. Compared with Conventional THA (CoTHA), several studies have shown that robot-assisted THA (RaTHA) can improve the accuracy of implant placement, achieve equal leg length, enhance hip offset, decreases in length of stay and costs, but may increase the readmissions and blood transfusions [ 5 9 ].…”
Section: Introductionmentioning
confidence: 99%
“…The success of traditional THA depends largely on the precision of implant placement, which requires extensive surgical experience [ 3 ]. Furthermore, with the widespread adoption of THA, the number of patients requiring hip revision due to dislocations, impingement, pelvic osteolysis, acetabular displacement, polyethylene wear, and unequal leg length is increasing, seriously affecting patient satisfaction and quality of life [ 4 ]. Compared with Conventional THA (CoTHA), several studies have shown that robot-assisted THA (RaTHA) can improve the accuracy of implant placement, achieve equal leg length, enhance hip offset, decreases in length of stay and costs, but may increase the readmissions and blood transfusions [ 5 9 ].…”
Section: Introductionmentioning
confidence: 99%
“…It is difficult to perform accurate manual prosthesis positioning and implantation. Consequently, aseptic loosening, dislocation, leg length discrepancy (LLD), wear to the prosthesis surface, in addition to other problems, remain to be solved [3,4]. This often leads to early revision surgery, affecting the quality of life for patients and also imposes an additional financial burden.…”
Section: Introductionmentioning
confidence: 99%
“…Several modifiable and nonmodifiable risk factors should be considered prior to undertaking hip arthroplasty. Modifiable risk factors include tobacco, alcohol use, and obesity [15,16]. Modern hip arthroplasty utilizing press fit implants relies on Femoral offset and subsequent abductor moment arm [13].…”
Section: Risk Factorsmentioning
confidence: 99%