2011
DOI: 10.1109/tdei.2011.6118638
|View full text |Cite
|
Sign up to set email alerts
|

Installing insulation jacket to improve outdoor insulation performance of composite insulator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
7
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 12 publications
0
7
0
Order By: Relevance
“…Indeed, reports about failures involving polymer insulators have increased in recent years [4][5][6]. As a consequence, studies about corona formation mechanism and its impacts on polymer insulators have been growing in the last years [7][8][9][10][11][12][13][14][15][16][17].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Indeed, reports about failures involving polymer insulators have increased in recent years [4][5][6]. As a consequence, studies about corona formation mechanism and its impacts on polymer insulators have been growing in the last years [7][8][9][10][11][12][13][14][15][16][17].…”
Section: Introductionmentioning
confidence: 99%
“…The hydrophobicity of different contaminated surfaces was investigated, and the results show that water droplets change the E-field and reduce corona onset voltage. Experiments with jacket installation to improve composite insulator performance were performed by Mei et al [10]. Gubanski et al and Ma et al presented a broad review on the mechanism of faults and diagnostic methods of polymer insulation [2,[11][12].…”
Section: Introductionmentioning
confidence: 99%
“…Calculation result indicates the voltage distribution along the whole insulator string appears to be a "U" style distribution. [12][13].…”
Section: Introductionmentioning
confidence: 99%
“…Mei designed a silicone rubber jacket installed at the live end of composite insulator to change the capacitance distribution in order to reduce the extremely high electric field strength. Flashover voltage of the composite insulator was thus increased [12]. Dry insulator has extremely high insulation resistance; therefore the effect of insulation resistance can be neglected while analyzing the electric field distribution of insulator.…”
Section: Introductionmentioning
confidence: 99%
“…This system allows redistributing the voltage gradients in the vicinities of the protected high voltage devices and lowering the maximum value of the voltage gradient below the corona threshold, thus minimizing corona activity. It is well known that when the voltage gradient surpasses the surrounding air dielectric strength, corona discharges initiate [1]. When operating under high voltage transmission systems, corona effect is of great concern because of their harmful effects.…”
Section: Introductionmentioning
confidence: 99%