1982
DOI: 10.1016/0010-2180(82)90130-4
|View full text |Cite
|
Sign up to set email alerts
|

Instantaneous CARS thermometry in turbulent flames

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

1983
1983
1993
1993

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(3 citation statements)
references
References 19 publications
0
3
0
Order By: Relevance
“…Regarding this, high data aquisition rates are favourable. However the pulse repetition rates for most of the standard CARS systems is determined by the commonly employed Nd : YAG laser (typically 10 or 20 Hz) [5][6][7][8]. In contrast, with an excimer-laserpumped CARS apparatus, much higher repetition rates can be achieved so that even for short time events a statistically sufficient number of data can be measured.…”
mentioning
confidence: 99%
“…Regarding this, high data aquisition rates are favourable. However the pulse repetition rates for most of the standard CARS systems is determined by the commonly employed Nd : YAG laser (typically 10 or 20 Hz) [5][6][7][8]. In contrast, with an excimer-laserpumped CARS apparatus, much higher repetition rates can be achieved so that even for short time events a statistically sufficient number of data can be measured.…”
mentioning
confidence: 99%
“…Information about a single rotational/vibrational energy level is insufficient to determine the temperature of the volume so a number of different energy levels must be probed. This can be done by scanning the frequency of the Stokes beam or by generating Presented as Paper 90-5260 at the AIAA 2nd International Aerospace Planes Conference, Orlando, FL, Oct. 29-31, 1990; received Dec. 3,1990; revision received June 1,1992; accepted for publication June 3, 1992 a number of frequencies all at once. In the second approach called "broadband" CARS, a Stokes beams containing a band of wavelengths is created.…”
Section: Oherent Anti-stokes Raman Spectroscopy (Cars)mentioning
confidence: 99%
“…On the receiving side, the anti-Stokes beam partially overlapped the other pump beam. Since the blue anti-Stokes beam which contained the signal was very weak compared to the green pump beam, it was separated from the pump using a multipass dichroic cavity (as was done by Fujii et al 3 ). Each time the green and blue beams struck a cavity mirror 98% of the blue was reflected and 90% of the green was passed, thus separating the signal from the interference.…”
Section: A Optical Apparatusmentioning
confidence: 99%