Instantaneous Specific Protection Method Against Faulty Synchronizations of Synchronous Machines

Abstract: The probability of faulty synchronization of a generator is very small, but not impossible. The main cause of a faulty synchronization is due to wiring errors caused during maintenance or commissioning when voltage transformer and synchronizing equipment are connected or reconnected wrongly. Faulty synchronizations of synchronous generators cause overcurrent and high electromagnetic torque values that can severely damage, not only the generators their selves, but also prime movers and step-up transformers. Mor… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 25 publications
0
2
0
Order By: Relevance
“…where i d Load is the load current along the d-axis. The inverter's output voltage along the q-axis, U q C , is shown in Equation (23).…”
Section: Model Of Energy Storage Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…where i d Load is the load current along the d-axis. The inverter's output voltage along the q-axis, U q C , is shown in Equation (23).…”
Section: Model Of Energy Storage Systemmentioning
confidence: 99%
“…Currently, various protection devices [22,23] are widely used to determine the degree of power quality, allowing operation if the controlled parameters (voltage and frequency) of the parallel-operating power sources are within acceptable limits. Depending on the levels of deviation of the controlled parameters, these devices form control signals to disconnect the power source from the MSB, resynchronizing it or unloading the power sources by tripping non-essential consumers.…”
mentioning
confidence: 99%
“…As a result of the wrong synchronization resulting from the unequal values of voltages, a disturbance occurred in the various variables of both machines. It is assumed that the angular velocity of both machines and therefore the frequencies are equal, but due to the wrong synchronization, the difference increases between them due to growth of the reduction in the excitation level of the rotor of the second machine, and as shown in the figures (6,7). Because of the wrong synchronization, the terminal voltage of both machines decrease with the decrease in the excitation level of the second generator rotor, as shown in the figure (8).…”
Section: Simulation and Results At Under Excitation Faulty Synchroniz...mentioning
confidence: 99%
“…The main cause of a faulty synchronization is due to, human errors, when voltage transformer and synchronizing equipment are connected or reconnected wrongly during maintenance leads to wiring errors and error ratio of voltage transformers. This deviation produces a high sudden reactive power flow either into the generator or into the power system, according to the voltage difference sign [6].…”
Section: Causes Of Poor Rms Voltage Matchingmentioning
confidence: 99%