2010
DOI: 10.1016/j.jelekin.2008.12.001
|View full text |Cite
|
Sign up to set email alerts
|

Instrumentation for measuring dynamic spinal load moment exposures in the workplace

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
21
0
2

Year Published

2010
2010
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 28 publications
(23 citation statements)
references
References 18 publications
0
21
0
2
Order By: Relevance
“…Many lifting tasks can thus be simulated with little effort using four input variables. The required input data on trunk rotation (from upright), lumbar curvature (or pelvic rotation from upright) and load position in different tasks should be estimated either accurately (by proper equipments such as video camera motion analysis systems, inclinometers, sensors) (Marras et al, 2010) or based on simple measurement devices (e.g., bathroom scale and tape measure) and experienced guess followed by some parametric sensitivity studies within reasonable input limits. In case the pelvic rotation (P) is not known in a lifting activity, one may evaluate the L/P ratio exploiting available in vivo data (Fig.…”
Section: Discussionmentioning
confidence: 99%
“…Many lifting tasks can thus be simulated with little effort using four input variables. The required input data on trunk rotation (from upright), lumbar curvature (or pelvic rotation from upright) and load position in different tasks should be estimated either accurately (by proper equipments such as video camera motion analysis systems, inclinometers, sensors) (Marras et al, 2010) or based on simple measurement devices (e.g., bathroom scale and tape measure) and experienced guess followed by some parametric sensitivity studies within reasonable input limits. In case the pelvic rotation (P) is not known in a lifting activity, one may evaluate the L/P ratio exploiting available in vivo data (Fig.…”
Section: Discussionmentioning
confidence: 99%
“…Detailed descriptions of the instrumentation and performance can be found elsewhere. 11 Force measurement accuracy is within 0.5 kg (1.1 lb. ), and position accuracy (average absolute error) is within 3.0 cm (1.2 in.).…”
Section: Health Effects Samplingmentioning
confidence: 92%
“…In this study, a state-of-the art moment monitor capable of quantifying numerous physical exposure variables over the course of a workday 11 was used to assess exposure in distribution center environments. The goal of this study was to assess the relationship between exposures to physical factors in such environments and changes in low back function over time.…”
mentioning
confidence: 99%
“…The provision of constant exposure tracking system, 26 the Lumbar Motion Monitor (BioDynamic Solutions, Inc, Columbus, OH), 24,25,28 and computerassisted recording and long-term analysis of musculoskeletal load measurement 14 are all relatively complex and cumbersome and achieve measurement accuracy at the expense of reduced portability and simplicity.…”
Section: T T Conclusionmentioning
confidence: 99%