1978
DOI: 10.1088/0022-3735/11/1/001
|View full text |Cite
|
Sign up to set email alerts
|

Instruments for use in electrode process research

Abstract: The review covers the elementary aspects of construction and use of instruments for electrode process research, dealing with both electrochemical and biological applications where these methodologies overlap. There is a guide to desirable specifications in commercial instrumentation and a list of manufacturers of equipment.2*

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

1982
1982
2017
2017

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 24 publications
(7 citation statements)
references
References 35 publications
0
7
0
Order By: Relevance
“…It has several advantages such as simplicity and very sensitive to small current when using high resistor value on the feedback [16,17]. In the other hand, it also has disadvantages; it produces some noises caused by the EMI at the WE due to its virtual Ground (GND) connection, the circuit only work with bipolar power supply [18], and op-amp bias current may influence the measurement result. In this experiment we eliminated these problems by using a low bias current op-amp, adding Butterworth filter to reduce the noises, and implementing the voltage reference at the trans-impedance circuit to bring the output above the ground potential.…”
Section: Literature Review a Amperometric Electro-chemical Biosementioning
confidence: 99%
“…It has several advantages such as simplicity and very sensitive to small current when using high resistor value on the feedback [16,17]. In the other hand, it also has disadvantages; it produces some noises caused by the EMI at the WE due to its virtual Ground (GND) connection, the circuit only work with bipolar power supply [18], and op-amp bias current may influence the measurement result. In this experiment we eliminated these problems by using a low bias current op-amp, adding Butterworth filter to reduce the noises, and implementing the voltage reference at the trans-impedance circuit to bring the output above the ground potential.…”
Section: Literature Review a Amperometric Electro-chemical Biosementioning
confidence: 99%
“…Measurement Based on PSoC Strahinja P. Janković, Student Member, IEEE, Vujo R. Drndarević, Member, IEEE system is increased and calibration is required. Another possibility is to use the potentiostat technique [13], [14]. For providing a constant voltage supply for the device under test (DUT), operational amplifier with negative feedback is used.…”
Section: Microcontroller Power Consumptionmentioning
confidence: 99%
“…An op-amp capable of handling capacitive loads drives the CE, while a high-impedance precision op-amp in buffer configuration senses the voltage at the RE, closing the feedback loop via adder circuit. Because the electrochemical cell is part of the feedback loop of the drive op-amp, oscillations may occur in some experimental setups despite the op-amp's internal compensation for capacitive loads [24, 25]. The nonlinear nature of electrochemical cells requires additional flexible compensation to stabilize the potentiostat circuit over a wide range of experimental conditions and to minimize the necessity of external components to tame oscillatory behavior.…”
Section: Instrumentsmentioning