Handbook of Environmental Materials Management 2018
DOI: 10.1007/978-3-319-58538-3_122-1
|View full text |Cite
|
Sign up to set email alerts
|

Integrated Evaluation of Quantitative Factors Related to the Environmental Quality Scenario

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 58 publications
0
2
0
Order By: Relevance
“…Upon entering the impactor, the sample flow is divided into two separate flow systems, and the air sample is fractionated, usually at a flow rate of 16.7 L/min, due to the acceleration that occurs in the particles. Thus, PM2.5-10 particles are directed directly to the first deposition chamber and deposited on a membrane filter, while PM2.5 particles are directed through a tube that channels the flow and are collected separately on another membrane (Costa et al, 2018). For field sampling, the "transect" method described by Filgueiras et al (1994) was applied, adapted for bird observation, where species are recorded through visual sightings and vocalizations along a route.…”
Section: Monitoring and Analysis Of Particulate Mattermentioning
confidence: 99%
“…Upon entering the impactor, the sample flow is divided into two separate flow systems, and the air sample is fractionated, usually at a flow rate of 16.7 L/min, due to the acceleration that occurs in the particles. Thus, PM2.5-10 particles are directed directly to the first deposition chamber and deposited on a membrane filter, while PM2.5 particles are directed through a tube that channels the flow and are collected separately on another membrane (Costa et al, 2018). For field sampling, the "transect" method described by Filgueiras et al (1994) was applied, adapted for bird observation, where species are recorded through visual sightings and vocalizations along a route.…”
Section: Monitoring and Analysis Of Particulate Mattermentioning
confidence: 99%
“…The equipment performs the inertial separation of ne and coarse particles by a virtual impactor, dividing the sample ow into two separate systems and fractioning the air sample at a sampling ow rate of 900 L min − 1 (PM 2.5 ) and 100 L min − 1 (PM 2.5−10 ). The PM 2.5−10 particles are directed to the rst deposition layer and deposited on a 47 mm diameter polycarbonate membrane lter, while the PM 2.5 particles are collected separately in another membrane with the same speci cation (Costa et al, 2018).…”
Section: Particulate Matter Samplingmentioning
confidence: 99%