2021
DOI: 10.1016/j.enconman.2021.114235
|View full text |Cite
|
Sign up to set email alerts
|

Integration of concentrated multi-junction solar cells with small-scale organic rankine cycle

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 57 publications
0
5
0
Order By: Relevance
“…The linear driving force model was used to define the adsorption/desorption rate, Equation (23). K LDF is the overall intra-particle mass-transfer coefficient, A = 132.89 s −1 , E a = 22.97 kJ•mol −1 , and R u = 8.314 kJ•kmol −1 •K −1 denote the pre-exponential constant, activation energy, and universal gas constant, respectively [41].…”
Section: Adsorption Isotherms and Kineticsmentioning
confidence: 99%
See 1 more Smart Citation
“…The linear driving force model was used to define the adsorption/desorption rate, Equation (23). K LDF is the overall intra-particle mass-transfer coefficient, A = 132.89 s −1 , E a = 22.97 kJ•mol −1 , and R u = 8.314 kJ•kmol −1 •K −1 denote the pre-exponential constant, activation energy, and universal gas constant, respectively [41].…”
Section: Adsorption Isotherms and Kineticsmentioning
confidence: 99%
“…Maximum energy conversion efficiency for the entire system was 68.47 percent. A CPV/T system with an integrated small-scale ORC was examined by Alamri et al [23], utilizing various working fluids. According to their findings, the system converted solar energy into electricity with a total efficiency of 46.57 percent when R245fa was used as the working fluid.…”
Section: Introductionmentioning
confidence: 99%
“…To balance computational time and solution accuracy, 6.44 × 10 5 elements was chosen with relatively little error. The focal spot under outdoor conditions has been compared to other theoretical studies for a 10 mm 2 solar cell with no heat sink under a geometric concentration ratio of 500 suns, Aldossary et al [3] assumes uniform illumination as is standard within the literature, Alamri et al [7] use COMSOL's Ray Optics physics package. As is seen in Fig.…”
Section: Theoretical Validationmentioning
confidence: 99%
“…At 1500 suns, the solar cell efficiency reached 35.7% and the total system exegetic efficiency reached 35.0% when modelled with uniform irradiance. Alamri et al [6,7] combined COMSOL Multiphysics' Ray Optics and Heat Transfer in Solids and Fluids physics packages. The cooling system is simple as the focus is placed on the ray tracing section.…”
Section: Introductionmentioning
confidence: 99%
“…Besides having several advantages, a major advantage of ORC is that the system can be applied at a small scale compared to the water/steam RC systems [7]. Different energy sources like biomass, geothermal, and industrial waste heat other than solar energy can also be integrated with the ORC system for power generation [8][9][10][11][12][13][14][15]. For future sustainable energy systems, utilization of the organic fluid for the energy extraction from the exhaust heat from different energy sources is a viable option for the waste heat recovery system.…”
Section: Introductionmentioning
confidence: 99%