2020
DOI: 10.18502/ijph.v49i8.3865
|View full text |Cite
|
Sign up to set email alerts
|

Intensive Care Unit Risk Assessment: A Systematic Review

Abstract: Background: It is of paramount importance to reduce the probability of clinical risks to improve the quality of health care services, make the relationship between service providers and patients more effective, enhance patient satisfaction, and decrease the rate of complaints regarding medical errors in hospitals. This study aimed at detecting potential and unacceptable risks occurring in the hospital ICUs. Methods: In this systematic review, all studies examining the risk assessment of ICUs in hospitals… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
1
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 26 publications
0
3
1
1
Order By: Relevance
“…In the case of the volumetric ventilator, the highest priority causes are related to the operator's handling of equipment components, particularly the filter and the power cable. When complementing the Ishikawa diagram analysis, a situation similar to the one presented In general, the found results contrast with those of other studies that used the FMEA method in the ICU, where the failures with the highest priority related to alarms of the ventilation device 17 or increased rates of internal infection due to the inadequate operation of the medical equipment 18 are reported. It is important to note that the FMEA method's application in each case depends on the quantity and quality of the information collected and that the value of the results will be maintained in direct relation to its updating.…”
Section: Discussioncontrasting
confidence: 56%
“…In the case of the volumetric ventilator, the highest priority causes are related to the operator's handling of equipment components, particularly the filter and the power cable. When complementing the Ishikawa diagram analysis, a situation similar to the one presented In general, the found results contrast with those of other studies that used the FMEA method in the ICU, where the failures with the highest priority related to alarms of the ventilation device 17 or increased rates of internal infection due to the inadequate operation of the medical equipment 18 are reported. It is important to note that the FMEA method's application in each case depends on the quantity and quality of the information collected and that the value of the results will be maintained in direct relation to its updating.…”
Section: Discussioncontrasting
confidence: 56%
“…The outcome of the study was mortality during ICU stay. The predictors were primarily selected based on a consensus of the authors considering the limits of time, budget, and personnel [ 15 , 16 ]. We recorded patients’ sex and age, significant comorbidities, vital signs, information on nosocomial infections if any, the reason for admission, arterial blood gas, and a number of other laboratory test results, GCS on admission or immediately before EI (for patients undergoing EI), and significant procedures (including EI).…”
Section: Methodsmentioning
confidence: 99%
“…Such initiatives improve employee satisfaction, reduce burnout, and enhance staff retention. A content and motivated healthcare workforce is more likely to provide compassionate and efficient patient care, contributing to an overall positive hospital reputation and patient outcomes [ 41 ].…”
Section: Reviewmentioning
confidence: 99%