2016
DOI: 10.1016/j.knee.2015.08.017
|View full text |Cite
|
Sign up to set email alerts
|

Inter- and intra-rater reliability of patellofemoral kinematic and contact area quantification by fast spin echo MRI and correlation with cartilage health by quantitative T1ρ MRI

Abstract: Background Patellar maltracking is a leading cause of patellofemoral pain syndrome (PFPS). The aim of this study was to determine the inter- and intra-rater reliability of a semi-automated program for magnetic resonance imaging (MRI) based patellofemoral kinematics. Methods Sixteen subjects (10 with PFPS [mean age 32.3; SD 5.2; eight females] and six controls without PFPS 19 [mean age 28.6; SD 2.8; three females]) participated in the study. One set of T2-weighted, fat-saturated fast spin-echo (FSE) MRIs were… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(14 citation statements)
references
References 31 publications
0
14
0
Order By: Relevance
“…These regions of interest were then used to estimate patellar alignment using a previously developed software program, with good intraclass correlation coefficient values (>0.84) for intra- and interuser reliability. 16 First, the patellar and femoral coordinate systems were defined anatomically as previously described. 16 The segmented femoral bone in the knee-flexed position was then rigidly registered to that in the fully extended position by the use of an iterative closest-point shape-matching algorithm.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…These regions of interest were then used to estimate patellar alignment using a previously developed software program, with good intraclass correlation coefficient values (>0.84) for intra- and interuser reliability. 16 First, the patellar and femoral coordinate systems were defined anatomically as previously described. 16 The segmented femoral bone in the knee-flexed position was then rigidly registered to that in the fully extended position by the use of an iterative closest-point shape-matching algorithm.…”
Section: Methodsmentioning
confidence: 99%
“…16 First, the patellar and femoral coordinate systems were defined anatomically as previously described. 16 The segmented femoral bone in the knee-flexed position was then rigidly registered to that in the fully extended position by the use of an iterative closest-point shape-matching algorithm. Thus, the femur was held fixed to allow calculation of patellar alignment relative to the femoral coordinate system in each knee-extended and knee-flexed position.…”
Section: Patellar Alignmentmentioning
confidence: 99%
“…Reporting SEM with the unit‐less ICC(2,1) enhances interpretation of repeatability, providing 95% confidence that true alignment is within one SEM of the point estimate. Lau et al evaluated 3D patellar alignment in participants with patellofemoral pain who were positioned supine and partially weight‐bearing (25% body weight). They reported SEM values that are comparable to our results (flexion 2.40°, spin 0.94°, tilt 0.98°, proximal translation 1.43 mm, lateral translation 1.10 mm, anterior translation 1.67 mm) .…”
Section: Discussionmentioning
confidence: 99%
“…Lau et al evaluated 3D patellar alignment in participants with patellofemoral pain who were positioned supine and partially weight‐bearing (25% body weight). They reported SEM values that are comparable to our results (flexion 2.40°, spin 0.94°, tilt 0.98°, proximal translation 1.43 mm, lateral translation 1.10 mm, anterior translation 1.67 mm) . This suggests that acquiring images in upright positions does not affect repeatability.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation