2017
DOI: 10.1049/joe.2017.0243
|View full text |Cite
|
Sign up to set email alerts
|

Inter‐area oscillation statistical analysis of the U.S. Eastern interconnection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

4
8
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 38 publications
4
8
0
Order By: Relevance
“…In the regime of resonant behaviour [21], we observe inter-area oscillations with period lengths of t = 7 s and t = 4.5 s, which we extract using a principal component analysis (PCA). These time scales agree well with frequencies of inter-area oscillations reported in other studies in Europe [60,61,64] but also in the US [65]. However, we notice that the time scales separating bulk, resonance and local behaviour are different than the authors in a theoretical work [21] assumed.…”
Section: Discussionsupporting
confidence: 89%
“…In the regime of resonant behaviour [21], we observe inter-area oscillations with period lengths of t = 7 s and t = 4.5 s, which we extract using a principal component analysis (PCA). These time scales agree well with frequencies of inter-area oscillations reported in other studies in Europe [60,61,64] but also in the US [65]. However, we notice that the time scales separating bulk, resonance and local behaviour are different than the authors in a theoretical work [21] assumed.…”
Section: Discussionsupporting
confidence: 89%
“…Inter-area mode, simply inter-area, oscillations are associated with a combination of closely coupled coherent generators or generating stations in a power system swinging with respect to another combination of closely coupled coherent generators or generating stations in another power system [1]. Stabilization of inter-area oscillations has been a matter of overwhelming concern in the power industry community because of their dangerous ramifications on the power network [1]. Power system oscillations impose critical loading limits on a transmission interface beyond which the secure operation of a power network is jeopardized [1,2].…”
Section: Introductionmentioning
confidence: 99%
“…Stabilization of inter-area oscillations has been a matter of overwhelming concern in the power industry community because of their dangerous ramifications on the power network [1]. Power system oscillations impose critical loading limits on a transmission interface beyond which the secure operation of a power network is jeopardized [1,2]. Inter-area oscillations are believed to be the root cause behind many widespread blackout events [1,2].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations