Inter-calibration of gamma dose rate detectors on the European scale

Abstract: Abstract.A project to compare the response of different detector types was started in 1996 at the Schauinsland mountain (1200 m above sea level) close to Freiburg, Germany, where the German office for radiation protection (BfS) runs a trace analysis laboratory since about 50 years. The aim of this inter-calibration experiment is to compare different gamma dose rate detector types over long periods and under rather unfavorable climatic conditions. This allows to characterise different probe types under environm… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…caesium 137), response to background radiation may vary considerably. These effects have been the subject of several studies (EURADOS, 1999;Pernicka and Kluson, 1996;Stohlker et al, 2009), and clearly show that instruments utilising different detection processes all have varying responses to background radiation. Background gamma radiation, as measured by an instrument, is composed of the following components:…”
Section: Calibrationmentioning
confidence: 95%
“…caesium 137), response to background radiation may vary considerably. These effects have been the subject of several studies (EURADOS, 1999;Pernicka and Kluson, 1996;Stohlker et al, 2009), and clearly show that instruments utilising different detection processes all have varying responses to background radiation. Background gamma radiation, as measured by an instrument, is composed of the following components:…”
Section: Calibrationmentioning
confidence: 95%
“…In addition, BfS operates an open field site for long-term observations at mount Schauinsland near Freiburg (INTERCAL facility). Up to 20 detectors from different countries are operated in parallel at this place, allowing a direct comparison of readings from all probes over long periods of time under variable climate conditions (5, 6) .…”
Section: Ader Detectorsmentioning
confidence: 99%
“…At the INTERCAL facility on mount Schauinsland near Freiburg (5, 6) , one additional probe was installed directly fixed on the wall of a building. In addition, one other detector was installed 1 m above ground in a small forest close to the INTERCAL facility.…”
Section: Measurement Uncertaintiesmentioning
confidence: 99%
“…The facility is located on the Schauinsland mountain (1200 m above sea level). In contrast to the above mentioned intercomparison experiments performed by the European Dosimetry group (EURADOS), the aim of this inter-calibration experiment (INTERCAL) is to compare different area dose rate detector types over long periods and under rather unfavorable climatic conditions [29]. In summer 2007, the INTERCAL facility was re-designed for the simultaneous operation of up to 20 different ARDM detectors under the same environmental conditions.…”
Section: Jinst 12 P12024mentioning
confidence: 99%