2015
DOI: 10.1061/(asce)gt.1943-5606.0001259
|View full text |Cite
|
Sign up to set email alerts
|

Interaction between Laterally Loaded Pile and Surrounding Soil

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 38 publications
(12 citation statements)
references
References 23 publications
0
12
0
Order By: Relevance
“…Figure 4b illustrates that the test pile was installed in the soil box with a distance to the boundary of approximately 8.8 pile diameters (8.8D). A recent test on a single steel rigid pile with a distance of 7.5D between the pile and the soil box boundary showed that the stresses measured near the box boundary were smaller than 1 kPa, confirming the minimal effect of the box boundary on the measured pile response (Lin et al 2014). The three pressure sheets, which were wrapped around the pile before installing it in the soil box, covered most of the pile length.…”
Section: Test Setup and Instrumentationmentioning
confidence: 78%
See 3 more Smart Citations
“…Figure 4b illustrates that the test pile was installed in the soil box with a distance to the boundary of approximately 8.8 pile diameters (8.8D). A recent test on a single steel rigid pile with a distance of 7.5D between the pile and the soil box boundary showed that the stresses measured near the box boundary were smaller than 1 kPa, confirming the minimal effect of the box boundary on the measured pile response (Lin et al 2014). The three pressure sheets, which were wrapped around the pile before installing it in the soil box, covered most of the pile length.…”
Section: Test Setup and Instrumentationmentioning
confidence: 78%
“…Two pressure sheets with dimensions of 33 x 33 cm and one pressure sheet with dimensions of 43 x 43 cm were used in the test. The accuracy of the tactile pressure measurements was discussed by Palmer et al (2009) andLin et al (2014), who concluded that the errors in pressure measurements were smaller than 10% for different soil conditions. The advanced sensors available at the facility also include shape acceleration arrays (SAAs), which are customized arrays of micro-machined electromechanical sensors that track three dimensional (3D) movement along the sensed length.…”
Section: Description Of Testing Facilitymentioning
confidence: 97%
See 2 more Smart Citations
“…In addition to the referred experimental e orts, numerical studies have been carried out by various codes and platforms. Some notable instances of such studies include: Finn et al [11], Tabesh & Poulos [12], Miyazaki et al [13], Finn and Fujita [14], Klar et al [15], Liyanapathirana and Poulos [16,17], Chang et al [18], Bhattacharya et al [19], Elgamal et al [20], Cheng and Jeremic [21], Cubrinovski et al [22], Rahmani and Pak [23], Asgari and Oliaei [24], Sarkar et al [25], Bouckovalas and Chaloulos [26], Asadi and Shari pour [27], and Lin et al [28].…”
Section: Literature Reviewmentioning
confidence: 99%