1993
DOI: 10.1016/0360-3016(93)90075-7
|View full text |Cite
|
Sign up to set email alerts
|

Interactive use of on-line portal imaging in pelvic radiation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
35
0

Year Published

1996
1996
2018
2018

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 75 publications
(37 citation statements)
references
References 8 publications
2
35
0
Order By: Relevance
“…Pelvic fields have been the subject of several studies of positioning accuracy (7,(11)(12)(13)23), since in general surveys of positioning accuracy (8,22) the pelvis was shown to be a site of relatively large errors, and because the pelvis is a site of high-dose curative treatment with the presence of * The mean values of the differences between the position of the respective points, or of the field size, in the simulation and treatment images (SIM-MV), the standard deviation (SD), the systematic variations, and the random variations. A negative value of a mean SIM-MV difference represents a mean shift of that point in the MV images in the right lateral (x) or cranial (y) direction.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Pelvic fields have been the subject of several studies of positioning accuracy (7,(11)(12)(13)23), since in general surveys of positioning accuracy (8,22) the pelvis was shown to be a site of relatively large errors, and because the pelvis is a site of high-dose curative treatment with the presence of * The mean values of the differences between the position of the respective points, or of the field size, in the simulation and treatment images (SIM-MV), the standard deviation (SD), the systematic variations, and the random variations. A negative value of a mean SIM-MV difference represents a mean shift of that point in the MV images in the right lateral (x) or cranial (y) direction.…”
Section: Discussionmentioning
confidence: 99%
“…Errors were larger when a mattress was used and with increasing patient diame ter. In a study of on-line portal imaging by De Neve et al (11), 566 parallel opposed pelvic fields were evaluated in 13 patients. Portal images were immediately evaluated and, whenever a visible error was detected, corrective table ad justments were applied using a telecontrolled patient couch.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…If the right dose per fi'action is used, the normal tissue will recover better in between the fractions than the tumor. As a consequence, a radiation treatment can consist of over 30 fractions and can last 2 months.…”
Section: Radiotherapymentioning
confidence: 99%