2021
DOI: 10.1111/ijlh.13748
|View full text |Cite
|
Sign up to set email alerts
|

Interchangeability of multiple Sysmex XN10 and XN20 modules for six types of leukocytes

Abstract: Introduction: Differential counts of leukocytes are frequent, and often several automated blood cell counters are needed in contemporary laboratories. However, these modules are often individually quality assured. Our aim was therefore to validate the interchangeability of five hematology modules in a large modern laboratory and to compare them with our gold standard (GS) manual white blood cell differential count.Methods: At Copenhagen University Hospital, we compared five Sysmex XNmodules for neutrophils, ly… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…We also found that there were no significant differences in the counts of non‐basophil leukocytes between the automated analyser and manual differential, which further supports the comparatively greater discrepancy in basophil counts. The Sysmex XN platform is one of the most widely used analysers and has been previously reported to undercount basophils when compared to other automated analysers and manual differential 18 . Furthermore, for the Sysmex XN, discrepancies in counts have been observed only for basophils and not for other leukocytes 18,19 .…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…We also found that there were no significant differences in the counts of non‐basophil leukocytes between the automated analyser and manual differential, which further supports the comparatively greater discrepancy in basophil counts. The Sysmex XN platform is one of the most widely used analysers and has been previously reported to undercount basophils when compared to other automated analysers and manual differential 18 . Furthermore, for the Sysmex XN, discrepancies in counts have been observed only for basophils and not for other leukocytes 18,19 .…”
Section: Discussionmentioning
confidence: 99%
“…The Sysmex XN platform is one of the most widely used analysers and has been previously reported to undercount basophils when compared to other automated analysers and manual differential. 18 Furthermore, for the Sysmex XN, discrepancies in counts have been observed only for basophils and for other leukocytes. 18,19 Our results show this trend is consistent in patients with myeloid neoplasms.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation