2003
DOI: 10.1021/ac0203746
|View full text |Cite
|
Sign up to set email alerts
|

Interfaces To Connect Thin-Layer Chromatography with Electrospray Ionization Mass Spectrometry

Abstract: This study has developed two interfaces to connect small-size thin-layer chromatography (TLC) with electrospray ionization mass spectrometry (ES-MS) for the continuous analysis of organic mixtures. The interfaces are (1) two bound optical fibers inserted into the C18-bonded particles at the exit of a small TLC channel and (2) a small commercial TLC strip with a sharpened tip. A reservoir continuously supplied a makeup solution to the tip of the TLC channel. The high voltage required for electrospray ionization… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
37
0

Year Published

2005
2005
2015
2015

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 55 publications
(38 citation statements)
references
References 18 publications
1
37
0
Order By: Relevance
“…When methanol, a solvent that favored elution of proteins, was used as the solvent, lysozyme signals were detected with low salt interferences ( Figure S2b). However, such large molecules were found to have difficulty being carried through and detected if they were loaded too far away from the tip cusp, similar to the observation in TLC [28,29].…”
Section: Separation Property Of Wooden Tipssupporting
confidence: 74%
“…When methanol, a solvent that favored elution of proteins, was used as the solvent, lysozyme signals were detected with low salt interferences ( Figure S2b). However, such large molecules were found to have difficulty being carried through and detected if they were loaded too far away from the tip cusp, similar to the observation in TLC [28,29].…”
Section: Separation Property Of Wooden Tipssupporting
confidence: 74%
“…For comparison, the TOF-SIMS detection limits of adsorbed proteins were investigated on four model substrates: mica, poly(tetrafluoroethylene), allyl amine plasma, and heptyl amine plasma polymer. in this study [28]. MALDI TOF-MS detection limits for AA and GA in this experiment were not established.…”
Section: Chromatographic Resolution and Tof-sims Selectivitymentioning
confidence: 66%
“…Raman spectroscopy layer a monolithic silica a SIMS-interfacing modified Si 60 layer (5) while in the positively charged ion macroscan the order changed [28]:…”
Section: Tof-sims Analyses Of Diterpenoic Acids On Chromatographic Sumentioning
confidence: 99%
See 2 more Smart Citations