“…Further, the results of microstructural examination using SEM on extruded CSES and CSI solder joints revealed no cracks or debonding at the interface which means the interfacial integrity was good (see Figures 13 and 15 bonding between the substrate and solder mostly depends on the integrity of the intermetallic compound (IMC) layer. e long-term reliability of solder joints depends on how, at the interface, IMCs are formed as reaction products between the solder and the substrate during soldering [38][39][40][41][42]. In this study, IMCs were clearly observed in Cu/ SAC305/Cu solder joints (see Figures 13(a) Figures 13(a), 13(c), 13(e), 13(g), 13(i), 13(k), 13(m), and 13(o)) had slightly less thickness than CSI (before and after corrosion) solder joints (see Figures 13(b), 13(d), 13(f ), 13(h), 13(j), 13(l), 13(n), and 13(p), which reduced the brittleness in CSES joints thus making CSES solder joints marginally better in strength than CSI solder joints.…”