2016
DOI: 10.1016/j.supflu.2015.10.013
|View full text |Cite
|
Sign up to set email alerts
|

Interfacial tension and gas solubility of molten polymer polyethylene glycol in contact with supercritical carbon dioxide and argon

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 25 publications
(16 citation statements)
references
References 40 publications
0
16
0
Order By: Relevance
“…The experimental data are shown in Figures 4 and 5. The authors have also investigated the solubility of CO 2 in the systems CO 2 + PEG 1500 and argon + PEG 1500 at temperature ranges from 328 K, to 363 K. 149 Jin et al investigated the solubility of poly(vinylpyrrolidone) (PVP) with molecular weights of 10 kg•mol −1 , 24 kg•mol −1 , 58 kg•mol −1 in CO 2 . Poly(vinylpyrrolidone) is one of the of the most important supplementary materials in the preparation of drugs.…”
Section: System Investigatedmentioning
confidence: 99%
See 2 more Smart Citations
“…The experimental data are shown in Figures 4 and 5. The authors have also investigated the solubility of CO 2 in the systems CO 2 + PEG 1500 and argon + PEG 1500 at temperature ranges from 328 K, to 363 K. 149 Jin et al investigated the solubility of poly(vinylpyrrolidone) (PVP) with molecular weights of 10 kg•mol −1 , 24 kg•mol −1 , 58 kg•mol −1 in CO 2 . Poly(vinylpyrrolidone) is one of the of the most important supplementary materials in the preparation of drugs.…”
Section: System Investigatedmentioning
confidence: 99%
“…The experimental data are shown in Figures and . The authors have also investigated the solubility of CO 2 in the systems CO 2 + PEG 1500 and argon + PEG 1500 at temperature ranges from 328 K, to 363 K …”
Section: System Investigatedmentioning
confidence: 99%
See 1 more Smart Citation
“…This technique uses a polymer that is exposed to fluids under supercritical conditions, which causes plasticization of the polymer matrix and lowers the glass transition and melting temperature. After depressurization, CO 2 is released, and thermodynamic instability determines the supersaturation of dissolved carbon dioxide in the polymer matrix and cell nucleation takes place, as suggested by Karvanja et al [ 123 ]. Unfortunately, there are limitations to this method as the interaction between supercritical CO 2 and the polymer matrix is limited to low T g amorphous or semicrystalline regions only [ 124 , 125 ].…”
Section: Other Processes Using Supercritical Fluids In the Polymermentioning
confidence: 99%
“…Prior to supercritical processing, the emulsion was pipetted into the small cylindrical mold and then immediately placed into a high-pressure view equilibrium cell made of stainless steel (Sitec AG, Zurich, CH) ( Figure 1). 13 The high-pressure cell was pressurized to 12 MPa with CO 2 by a high-pressure pump (NWA PM-101). The pressure inside the cell was measured by an electronic pressure gauge (WIKA Alexander Wiegand GmbH & Co. KG, Alexander-Wiegand-Straße, Klingenberg, Germany).…”
Section: Scaffold Preparation In Sccomentioning
confidence: 99%