Interference‐free mass spectrometric detection of capillary isoelectric focused proteins, including charge variants of a model monoclonal antibody

Abstract: CIEF represents an elegant technique especially for the separation of structural similar analytes, whereas MS is a state-of-the-art instrumentation for the identification and characterization of biomolecules. The combination of both techniques can be realized by hyphenating CIEF with CZE-ESI-MS applying a mechanical valve. During the CZE step, the remaining ESI-interfering components of the CIEF electrolyte are separated from the analytes prior to MS detection. In this work, a multiple heart-cut approach is pr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
33
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 35 publications
(33 citation statements)
references
References 20 publications
0
33
0
Order By: Relevance
“…162, 163 For compatibility with small transfer volumes and cIEF high voltages a multi-port valve and sample loop system was implemented, 163 and an evaluation of sample transfer loop volumes for efficiency and peak width was done. 162 IEF separation for p I range of 5–10 is applied to the analysis of charge variants of mAbs. In 3 h up to 6 analytes were transferred from cIEF to CZE-MS with the ability to detect a mass differences of 2 Da between mAb variants.…”
Section: Applications Of Ce and Mcementioning
confidence: 99%
“…162, 163 For compatibility with small transfer volumes and cIEF high voltages a multi-port valve and sample loop system was implemented, 163 and an evaluation of sample transfer loop volumes for efficiency and peak width was done. 162 IEF separation for p I range of 5–10 is applied to the analysis of charge variants of mAbs. In 3 h up to 6 analytes were transferred from cIEF to CZE-MS with the ability to detect a mass differences of 2 Da between mAb variants.…”
Section: Applications Of Ce and Mcementioning
confidence: 99%
“…for the separation of charge variants . There are also multidimensional approaches, for example CE‐MS , HPLC‐MS , or CE‐CE . These procedures offer a lot of analytical information, but are expensive and time consuming.…”
Section: Introductionmentioning
confidence: 99%
“…CEC is a hybrid technique between CE and HPLC and was recently used by Zhang et al for the separation of charge variants [37]. There are also multidimensional approaches, for example CE-MS [38,39], HPLC-MS [40][41][42][43][44], or CE-CE [45]. These procedures offer a lot of analytical information, but are expensive and time consuming.…”
mentioning
confidence: 99%
“…The evident benefits of CIEF and MS coupling regarding the high resolving power of p I ‐based separations and the unequivocal MS identification of individual peaks have promoted several investigations . Our research group has previously shown the value of two‐dimensional systems using standard CE instrumentation for CIEF, CZE‐MS as second dimension and a nanoliter valve for the coupling . The four‐port valve (VICI AG International, Schenkon, Switzerland) allows the direct coupling of two capillary‐based techniques with high flexibility .…”
mentioning
confidence: 99%
“…When the iCIEF peak is in the sample loop, the valve is switched to position B where the loop is in the second dimension. PVA‐coated capillaries are connected to the valve for the second dimension. In this work, two different ways to transport the peaks from the sample loop to the MS were tested: flow injection (FI) (Fig.…”
mentioning