1987
DOI: 10.1039/an9871200903
|View full text |Cite
|
Sign up to set email alerts
|

Interference of ascorbic and isoascorbic acids in the spectrophotometric determination of nitrite by the diazotisation-coupling technique

Abstract: The problem of the interference of ascorbic and isoascorbic acids in the spectrophotometric determination of nitrite by the diazotisationcoupling technique is important because these substances are frequently added to cured meats containing nitrite. The chemistry of the reaction of ascorbic and isoascorbic acids with nitrite is discussed. The effect of pH on the reaction at room temperature and on digestion at 80°C was investigated. Two composite diazotisationcoupling reagents [sulphanilamide and N-( 1-naphthy… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
10
0

Year Published

1994
1994
2004
2004

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 18 publications
(11 citation statements)
references
References 0 publications
1
10
0
Order By: Relevance
“…The factor used to convert percentage N to percentage crude protein was 6.25. -Nitrite content (ppm) determined by the Norwitz-Keliher method [11], in which the NEDD concentration was doubled as described by Binstok et al [12]. -Nitrate content (ppm) determined by a method based on that of Miranda et al [13] where vanadium(III) reduces nitrate to nitrite.…”
Section: Analysis For the Storage Experimentsmentioning
confidence: 99%
See 1 more Smart Citation
“…The factor used to convert percentage N to percentage crude protein was 6.25. -Nitrite content (ppm) determined by the Norwitz-Keliher method [11], in which the NEDD concentration was doubled as described by Binstok et al [12]. -Nitrate content (ppm) determined by a method based on that of Miranda et al [13] where vanadium(III) reduces nitrate to nitrite.…”
Section: Analysis For the Storage Experimentsmentioning
confidence: 99%
“…-Nitrate content (ppm) determined by a method based on that of Miranda et al [13] where vanadium(III) reduces nitrate to nitrite. The digestion, clarification and filtration of the meat samples were performed as described by Norwitz and Keliher [11]. The filtrate (25 ml) was mixed with 12.5 ml NEDD (1 w/v in H 2 O), 12.5 ml SULF (2% w/v in 5% HCl), 25 ml of a saturated solution of VCl 3 in 1 M HCl and water to make 100 ml.…”
Section: Analysis For the Storage Experimentsmentioning
confidence: 99%
“…Although the AOAC method is very sensitive, low recoveries are reported when used for nitrite determination in meat due to the ascorbic acid interference [3]. Norwitz and Keliher [5] have proposed modifying the AOAC method (referred to here as the modified AOAC method) using an alkaline medium (0.01 M NaOH) for the digestion step and introducing a new step based on addition of a clarifying agent (ZnSO 4 ) for protein precipitation. In this way the centrifugation step can be replaced with a simple filtration step.…”
Section: Real Sample Analysismentioning
confidence: 99%
“…For spectrophotometric determinations the Norwitz & Keliher method [5] was followed. 5 g of homogenised meat were added to approximately 70 mL 0.01 M NaOH and blended.…”
Section: Spectrophotometric Proceduresmentioning
confidence: 99%