2017
DOI: 10.1088/1681-7575/aa648d
|View full text |Cite
|
Sign up to set email alerts
|

Interferometric 2D small angle generator for autocollimator calibration

Abstract: Small angle generators are simple devices for providing small angles traceable to the definition of the SI-unit radian. The most accurate ones use a laser interferometer for measurement of angular displacement. Small angle generators used for autocollimator calibration usually create angles around a single axis. A two-directional angle generator would be preferable, as it could more efficiently reveal artefacts related to angular displacement across both axes, such as orthogonality of the autocollimator's meas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 21 publications
(15 citation statements)
references
References 19 publications
0
15
0
Order By: Relevance
“…At a grating pitch of 70 µm, when the focal length difference of two collimators is 1% , 3% , and 5% , the variation amount ∆W of moiré fringe width in the range of 0 • -10 • with different angles θ can be calculated using (7), as shown in Figure 3. When there is a slight difference in the focal length of two collimators, the width of moiré fringe changes significantly.…”
Section: Collimator Focal Length Equation and Simulationmentioning
confidence: 99%
See 1 more Smart Citation
“…At a grating pitch of 70 µm, when the focal length difference of two collimators is 1% , 3% , and 5% , the variation amount ∆W of moiré fringe width in the range of 0 • -10 • with different angles θ can be calculated using (7), as shown in Figure 3. When there is a slight difference in the focal length of two collimators, the width of moiré fringe changes significantly.…”
Section: Collimator Focal Length Equation and Simulationmentioning
confidence: 99%
“…Currently, the collimator is developing towards the directions of lightweight and miniaturization. With regard to self-collimating optical instruments designed for various specialized fields, the focal length is one of the most important parameters of the collimator, and its accuracy plays a significant role in the use of precise optical systems [7,8]. However, the measurement accuracy of long focal length optical systems is easily affected by external factors, and the processing error of the lens in the manufacturing process also has significant influences on the measurement accuracy [1,9,10].…”
Section: Introductionmentioning
confidence: 99%
“…Traceability of autocollimators to the SI unit is obtained through a calibration against primary standards. Few National Metrology Institutes are able to calibrate autocollimators at the level of some tenths of microradian by means of top calibration facilities such as [7][8][9][10][11][12].…”
Section: Introductionmentioning
confidence: 99%
“…Conventionally, the three main optical methods for angle measurement with high resolution and accuracy are: interferometers, internal-reflection and autocollimators [4][5][6][7][8]. An interferometer utilizes phase information to measure angular and linear displacement with high signal-to-noise ratio and high resolution [9]. The internal-reflection effect can make a wide range of devices very stable and compact with high resolution [10].…”
Section: Introductionmentioning
confidence: 99%