Interlaboratory Variability in the Quantification of New Generation Antiepileptic Drugs Based on External Quality Assessment Data

Abstract: Summary:Purpose: To assess interlaboratory variability in the determination of serum levels of new antiepileptic drugs (AEDs).Methods: Lyophilised serum samples containing clinically relevant concentrations of felbamate (FBM), gabapentin (GBP), lamotrigine (LTG), the monohydroxy derivative of oxcarbazepine (OCBZ; MHD), tiagabine (TGB), topiramate (TPM), and vigabatrin (VGB) were distributed monthly among 70 laboratories participating in the international Heathcontrol External Quality Assessment Scheme (EQAS). … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
17
0

Year Published

2010
2010
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(17 citation statements)
references
References 18 publications
0
17
0
Order By: Relevance
“…A broad reference range of 20–200 ng/mL has been proposed [50]. Analytical issues have been a challenging problem in measurement of tiagabine serum/plasma concentrations, with some assays not achieving a low enough limit of sensitivity to measure the full range of clinically relevant free drug concentrations [160]. Multiple analytical methodologies have been reported for the measurement of tiagabine in plasma/serum including GC/MS [161] and HPLC [162].…”
Section: Tiagabinementioning
confidence: 99%
“…A broad reference range of 20–200 ng/mL has been proposed [50]. Analytical issues have been a challenging problem in measurement of tiagabine serum/plasma concentrations, with some assays not achieving a low enough limit of sensitivity to measure the full range of clinically relevant free drug concentrations [160]. Multiple analytical methodologies have been reported for the measurement of tiagabine in plasma/serum including GC/MS [161] and HPLC [162].…”
Section: Tiagabinementioning
confidence: 99%
“…The role of the TDM for TGB has not yet established. Nevertheless, its use in ascertaining compliance and manging patients that are overdosed would be helpful, provided that utmost care is dependent on ensuring the reliability of the analytical assay [206,207]. If morning were to be undertaken, sampling time in relation to dose is critical because large interdose fluctuation in concentrations occur consequent to the short half-life of drug.…”
Section: Tiagabine (Tgb)mentioning
confidence: 99%
“…If morning were to be undertaken, sampling time in relation to dose is critical because large interdose fluctuation in concentrations occur consequent to the short half-life of drug. Because serum TGB are in the nanomolar range, analytical methods are not simple and interlaboratory differences in analytical reliability is of great concern [207]. Several GC [208] and LC method with various detectors such as ECD [209] or MS [206] are available.…”
Section: Tiagabine (Tgb)mentioning
confidence: 99%
“…However, a clear relationship between tiagabine serum/plasma concentration and therapeutic efficacy has not yet been established, with a broad reference range of 20-200 ng/mL proposed (Patsalos et al, 2008;Uthman et al, 1998). For measurement of free drug concentrations, analytical sensitivity is an issue, with some assays having insufficiently low limits of sensitivity to measure clinically relevant free drug concentrations (Williams et al, 2003). Consequently, such analysis is only performed at specialized reference laboratories.…”
Section: Tiagabinementioning
confidence: 99%