2002
DOI: 10.1016/s0039-9140(02)00292-8
|View full text |Cite
|
Sign up to set email alerts
|

Internal solid contact sensor for the determination of doxycycline hydrochloride in pharmaceutical formulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0

Year Published

2007
2007
2017
2017

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 18 publications
(9 citation statements)
references
References 27 publications
0
9
0
Order By: Relevance
“…10 The procedures of pretreating a substrate electrode (Pt or GC) surface and of modifying PPy or Pan film on substrate in a three electrode-cell, i.e. disc electrode used as the working electrode, SCE as reference electrode and platinum wire electrode as counter electrode, by repeating potential scan method, and of preparation of ISCS by dipping-coating procedures are the same as described by Sun et al 5,6 The following conditions are used for preparation of PPy or Pan film on substrate for a sensor. Evaluation of the comprehensive quality of sensor 5,9 The value of CQI for a given sensor is caculated using the following equation: CQI = ΣfiPi, where fi denotes a weighting factor whose values are 0.38 for f1, 0.30 for f2, 0.22 for f3 and 0.10 for f4, respectively, and Pi denotes the devoting of one of performances, which include S (mV/decade), LR (M), LD (M) and T (s) which is defined as the time needed for the sensor to reach a stable potential value after a concentration step from 10 -4 to 10 -3 M of the primary ion, 11 to the value of CQI, and the values can be calculated from the following formula: P1 = S/20, P2 = lg[LR]upper limit -lg[LR]lower limit, P3 = aLDmax/LDi, P4 = b/Ti.…”
Section: Preparation Of Sensormentioning
confidence: 99%
See 3 more Smart Citations
“…10 The procedures of pretreating a substrate electrode (Pt or GC) surface and of modifying PPy or Pan film on substrate in a three electrode-cell, i.e. disc electrode used as the working electrode, SCE as reference electrode and platinum wire electrode as counter electrode, by repeating potential scan method, and of preparation of ISCS by dipping-coating procedures are the same as described by Sun et al 5,6 The following conditions are used for preparation of PPy or Pan film on substrate for a sensor. Evaluation of the comprehensive quality of sensor 5,9 The value of CQI for a given sensor is caculated using the following equation: CQI = ΣfiPi, where fi denotes a weighting factor whose values are 0.38 for f1, 0.30 for f2, 0.22 for f3 and 0.10 for f4, respectively, and Pi denotes the devoting of one of performances, which include S (mV/decade), LR (M), LD (M) and T (s) which is defined as the time needed for the sensor to reach a stable potential value after a concentration step from 10 -4 to 10 -3 M of the primary ion, 11 to the value of CQI, and the values can be calculated from the following formula: P1 = S/20, P2 = lg[LR]upper limit -lg[LR]lower limit, P3 = aLDmax/LDi, P4 = b/Ti.…”
Section: Preparation Of Sensormentioning
confidence: 99%
“…Previous experimental investigations 5,6 have found that the conditions/parameters of electropolymerization for pyrrole (or aniline) could affect the response performances of ISCSs to some extent.…”
Section: Optimization Of Preparation Of Ppy Filmmentioning
confidence: 99%
See 2 more Smart Citations
“…1.0 Â 10 22 -1.0 Â 10 26 M standard solutions of DC.Cl were also prepared using the same procedures described elsewhere. [6,11] …”
Section: Reagents and Materialsmentioning
confidence: 99%