2015
DOI: 10.1063/1.4916121
|View full text |Cite
|
Sign up to set email alerts
|

Interpretation of the vacuum ultraviolet photoabsorption spectrum of iodobenzene by ab initio computations

Abstract: Identification of many Rydberg states in iodobenzene, especially from the first and fourth ionization energies (IE1 and IE4, X(2)B1 and C(2)B1), has become possible using a new ultraviolet (UV) and vacuum-ultraviolet (VUV) absorption spectrum, in the region 29 000-87 000 cm(-1) (3.60-10.79 eV), measured at room temperature with synchrotron radiation. A few Rydberg states based on IE2 (A(2)A2) were found, but those based on IE3 (B(2)B2) are undetectable. The almost complete absence of observable Rydberg states … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
52
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
7
2

Relationship

4
5

Authors

Journals

citations
Cited by 59 publications
(52 citation statements)
references
References 49 publications
0
52
0
Order By: Relevance
“…VUV transmission spectra were measured on the AU-UV beam line at the ASTRID2 5 synchrotron at Aarhus University, Denmark (Palmer et al 2015). Thin films deposited on MgF 2 windows were placed in the lollipop sample holder, able to mount up to four samples.…”
Section: Methodsmentioning
confidence: 99%
“…VUV transmission spectra were measured on the AU-UV beam line at the ASTRID2 5 synchrotron at Aarhus University, Denmark (Palmer et al 2015). Thin films deposited on MgF 2 windows were placed in the lollipop sample holder, able to mount up to four samples.…”
Section: Methodsmentioning
confidence: 99%
“…The apparatus used for the measurement of photoabsorption spectra has also undergone several alterations, since that which was originally described in Eden et al 33 These changes have recently been described in Ref. 34, to where the reader is referred for more detail. Briefly, the gas cell has a path length of 15.5 cm and is fitted with a heated 1 Torr baratron capacitance manometer (Setra model 774).…”
Section: B Vuv Photoabsorptionmentioning
confidence: 99%
“…The experimental setup was reported in detail by Palmer et al [26] In brief, ag as cell with ap ath length of 15.5 cm was mounted on the output of the monochromator,w ith aM gF 2 window separating it from the UHV of the beam line. The experimental setup was reported in detail by Palmer et al [26] In brief, ag as cell with ap ath length of 15.5 cm was mounted on the output of the monochromator,w ith aM gF 2 window separating it from the UHV of the beam line.…”
Section: Vuv Measurementsmentioning
confidence: 99%