2018
DOI: 10.1016/j.ultrasmedbio.2018.03.029
|View full text |Cite
|
Sign up to set email alerts
|

Intra- and Inter-Observer Reproducibility of a 2-D Shear Wave Elastography Technique and the Impact of Ultrasound Experience in Achieving Reliable Data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
18
3
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 29 publications
(25 citation statements)
references
References 22 publications
3
18
3
1
Order By: Relevance
“…Several other studies using SWE have demonstrated good to excellent interobserver and intraobserver agreement 10,28 . In contrast, our study showed poor‐to‐moderate interobserver agreement on the ICC, with a mean liver stiffness difference of between 0.66 and 0.9 kPa on the Bland–Altman analysis.…”
Section: Discussioncontrasting
confidence: 83%
See 1 more Smart Citation
“…Several other studies using SWE have demonstrated good to excellent interobserver and intraobserver agreement 10,28 . In contrast, our study showed poor‐to‐moderate interobserver agreement on the ICC, with a mean liver stiffness difference of between 0.66 and 0.9 kPa on the Bland–Altman analysis.…”
Section: Discussioncontrasting
confidence: 83%
“…Several other studies using SWE have demonstrated good to excellent interobserver and intraobserver agreement. 10,28 In contrast, our study showed poor-tomoderate interobserver agreement on the ICC, with a mean liver stiffness difference of between 0.66 and 0.9 kPa on the Bland-Altman analysis. The interobserver agreement improved in later sessions, perhaps suggestive of a learning curve in SWE, which is supported by findings of other studies.…”
Section: Discussioncontrasting
confidence: 80%
“…However, when talking about the intra-observer reproducibility, LSM performed by the experienced examiner were more homogeneous (higher ICCs) meaning that experience may play a role in acquiring reliable LSM by THE system. This observation was also made in another study [ 25 ] that evaluated the reproducibility of a 2D-SWE system, with similar results as ours in what regards the operator experience in performing the elastographic technique.…”
Section: Discussionsupporting
confidence: 88%
“…UGAP values are expressed in dB/cm/ MHz or in dB/m. LOGIQ E10 ultrasound machine can also perform liver stiffness measurements for fibrosis evaluation using an accurate 2D-Shear Wave Elastography (2D-SWE) technique [20][21][22][23], but this type of evaluation was not included in the present study.…”
Section: Subjectsmentioning
confidence: 99%