2018
DOI: 10.1002/jum.14581
|View full text |Cite
|
Sign up to set email alerts
|

Intra‐ and Inter‐rater Reliability of Navigated Ultrasound in the Assessment of Pelvic Tilt in Symptom‐Free Young Adults

Abstract: The intra-rater reliability values achieved were suitable. Intraclass correlation coefficient values for inter-rater reliability remained below an acceptable level. Possible reasons and overcoming strategies were presented. The 95% limits of agreement were good, at less than ±2°.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
15
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(16 citation statements)
references
References 19 publications
1
15
0
Order By: Relevance
“…While intra-rater reliability values were good, inter-rater reliability remained below acceptable marks [16], showing that both raters were probably locating the bony landmarks differently. Differences in localizing the right and left ASIS could have led to these discrepancies.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…While intra-rater reliability values were good, inter-rater reliability remained below acceptable marks [16], showing that both raters were probably locating the bony landmarks differently. Differences in localizing the right and left ASIS could have led to these discrepancies.…”
Section: Discussionmentioning
confidence: 99%
“…An ultrasound device is connected to the central unit via universal serial bus (USB) The intra-rater reliability of the system when measuring PT angles was good to excellent and moderate to excellent for the supine and upright positions, respectively. Inter-rater reliability remained below the expected values, probably due to the imaging protocols, which were probably not described with enough detail [16].…”
Section: Measurement Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…The data used for the present purpose was collected during two studies with the use of the same measurement system. One study investigated the intra- and inter-rater reliability of a navigated ultrasound system in the assessment of PT in Symptom-Free Young Subjects (SFYS) [ 18 ]. The second study assessed PT in patients scheduled for THA [ 17 ].…”
Section: Methodsmentioning
confidence: 99%
“…In view of the above-referred findings the data of two previous studies [ 17 , 18 ] were treated in a secondary data analysis. The aim was to test for factors that significantly affect PT angles.…”
Section: Introductionmentioning
confidence: 99%