Intra-fraction motion of the prostate during treatment with helical tomotherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(19 citation statements)
references
References 23 publications
0
19
0
Order By: Relevance
“…Margins of 2.2, 2.1 and 2.1 in the LR, SI and AP directions were required for translational motion only, and inclusion of the effect of rotations and matching errors increased these margins to approximately 4 mm in the LR and 5 mm in the SI and AP directions. 39 In a similar analysis, larger margins of 11.30, 9.95 and 13.49 mm in the same directions were proposed by Murthy et al 40 Kilovoltage cone beam CT Hirose et al 41 evaluated dosimetric consequences using kV CBCT guidance with either 8-mm margins (5-mm margin posteriorly and superiorly) or 5-mm margins isotropically. They showed that even with bony set-up correction, the target coverage was sufficient with both margins.…”
Section: Use Of Daily Ultrasoundmentioning
confidence: 76%
See 1 more Smart Citation
“…Margins of 2.2, 2.1 and 2.1 in the LR, SI and AP directions were required for translational motion only, and inclusion of the effect of rotations and matching errors increased these margins to approximately 4 mm in the LR and 5 mm in the SI and AP directions. 39 In a similar analysis, larger margins of 11.30, 9.95 and 13.49 mm in the same directions were proposed by Murthy et al 40 Kilovoltage cone beam CT Hirose et al 41 evaluated dosimetric consequences using kV CBCT guidance with either 8-mm margins (5-mm margin posteriorly and superiorly) or 5-mm margins isotropically. They showed that even with bony set-up correction, the target coverage was sufficient with both margins.…”
Section: Use Of Daily Ultrasoundmentioning
confidence: 76%
“…27 The intrafraction motion pattern has been shown to differ between patients and even in different fractions for the same treatment course. 91 Intratreatment motion has been evaluated by imaging before and after radiation delivery 39,48,90,[98][99][100] or directly during treatment using implanted electromagnetic transponders (beacons). 20,101,102 Fluoroscopy can also be used for prostate tracking at the expense of increased imaging dose, but Crocker et al 103 argued that this dose could be significantly reduced if the imaging field size is tailored to specific patients.…”
Section: Accounting For Intrafraction Motionmentioning
confidence: 99%
“…This does not take into account rectal movements during the actual treatment fraction, which may be significant and may depend on the overall treatment time. 42,43 …”
Section: Discussionmentioning
confidence: 99%
“…Daily MVCT image guidance scans were acquired immediately prior to treatment delivery for the purposes of online target localisation [22]. Following our department protocol, scans were inspected for rectal dilation and if deemed excessive, remedial action was taken prior to delivery of radiation therapy [23].…”
Section: Methodsmentioning
confidence: 99%