Intra-observer and inter-observer errors in CT measurement of torsional profiles of lower limbs: a retrospective comparative study

Abstract: BackgroundThe purpose of this study was to determine errors in measurement of torsional profiles (TP) (torsional femoral angle, torsional tibial angle, and femoral ankle angle) among four orthopedic surgeons, experts, and non-experts in measurement, and the learning curve.MethodsTwenty-six lower extremities of 13 patients with spastic diplegia candidates for femoral/tibial derotational osteotomy had preoperative bilateral computer tomography (CT) scan grams to establish the TP. Each measurement was done by fou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…Sinus CT scans are an integral part of preoperative planning. The important structures in planning sinus surgery are insertion of middle turbinate and the uncinated process, the location of anterior ethmoidal artery, and Keros class, Infraorbital cells, position of the Agger nasi cell, and the anatomical variants located in the operative area [5][6][7][8][9][10].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Sinus CT scans are an integral part of preoperative planning. The important structures in planning sinus surgery are insertion of middle turbinate and the uncinated process, the location of anterior ethmoidal artery, and Keros class, Infraorbital cells, position of the Agger nasi cell, and the anatomical variants located in the operative area [5][6][7][8][9][10].…”
Section: Introductionmentioning
confidence: 99%
“…Particularly there have been major differences between an experienced observer and an inexperienced observer [8,11]. However, a study of shoulder CT scans showed that there can also be differences between equally experienced observers [12].…”
Section: Introductionmentioning
confidence: 99%
“…In the present study, we did not analyze the inter-observer and intra-observer errors. However, two experienced researchers with such image assessment (two surgeons) were involved in order to reduce these errors [ 17 ]. We could not analyze the parity of the women (nulliparous or multiparous) included, and this is the limitation of the study.…”
Section: Discussionmentioning
confidence: 99%
“…In human medicine, different diagnostic approaches such as clinical examination, 16,21 radiography, 13,22 computed tomography (CT), 12,[23][24][25] ultrasound, 26 and fluoroscopy 15,27 have been described for assessing TT. The accuracy of radiography 18 and CT 28 have been investigated in the first reports in veterinary medicine focusing on TT.…”
Section: Introductionmentioning
confidence: 99%