2019
DOI: 10.1177/1742271x19831720
|View full text |Cite
|
Sign up to set email alerts
|

Intra-rater reliability of transversus abdominis measurement by a novice examiner: Comparison of “freehand” to “probe force device” method of real-time ultrasound imaging

Abstract: A “free hand” real-time-ultrasound method is commonly applied to measure transversus abdominis. Potentially, this increases transversus abdominis measurement error due to uncontrolled variability in probe to skin force, inclination, and roll, particularly for novice examiners. This single-group repeated-measures reliability study compared the intra-rater reliability of transversus abdominis thickness and activation measurement by a novice examiner between free hand and a standardized probe force device method.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 36 publications
0
9
0
Order By: Relevance
“…A limitation of this study are that all the still images were extracted only from eligible participants, in a single site and with a single acquisition protocol [5]. To avoid overfitting to a single acquisition protocol, exams should be obtained on several sites.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…A limitation of this study are that all the still images were extracted only from eligible participants, in a single site and with a single acquisition protocol [5]. To avoid overfitting to a single acquisition protocol, exams should be obtained on several sites.…”
Section: Discussionmentioning
confidence: 99%
“…The false-positive loss (L F ) discourages the model from predicting a blob with no point annotations, in order to reduce the number of false positive predictions, and is described using equation (5).…”
Section: Lcfcn Lossmentioning
confidence: 99%
See 2 more Smart Citations
“…Recently, there was an interesting study [22] using a probe force device, which was used to examine the intra-rater reliability of the transverse abdominis by a novice examiner in comparison to the freehand method. This study [22] suggested that use of the device and view of real-time force, inclination or roll would be helpful in obtaining reliable values of abdominal muscle parameters during ultrasound imaging than the freehand method. In the same context, the current study showed a higher intra-rater reliability of obtaining TA muscle thickness using a custom-made holder with a oneaxis loadcell through real-time feedback compared to the freehand method.…”
Section: Discussionmentioning
confidence: 99%