1991
DOI: 10.2519/jospt.1991.13.6.329
|View full text |Cite
|
Sign up to set email alerts
|

Intramachine and Intermachine Reliability of the Biodex and Cybex®II for Knee Flexion and Extension Peak Torque and Angular Work

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
34
1
4

Year Published

2003
2003
2012
2012

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 73 publications
(44 citation statements)
references
References 6 publications
5
34
1
4
Order By: Relevance
“…Gross et al 13) reported ICCs of between 0.92 and 0.97 in a study using two types of isokinetic dynamometers to measure the force of knee extensions performed at 60 degrees/s and 180 degrees/s. Wikholm et al 7) and Agre et al 8) reported that the interrater reliability of strength measurements made using a HHD was poorer for the lower than the upper limbs.…”
Section: Discussionmentioning
confidence: 99%
“…Gross et al 13) reported ICCs of between 0.92 and 0.97 in a study using two types of isokinetic dynamometers to measure the force of knee extensions performed at 60 degrees/s and 180 degrees/s. Wikholm et al 7) and Agre et al 8) reported that the interrater reliability of strength measurements made using a HHD was poorer for the lower than the upper limbs.…”
Section: Discussionmentioning
confidence: 99%
“…Only data recorded within 0.1°/second of 60°/second were included. The reliability of windowed data on concentric knee flexion and extension has been reported as r ϭ 0.90 -0.96 on Biodex systems (32). For each muscle group, the 5 peak windowed values for flexion and extension were averaged for each participant.…”
Section: Pathophysiologic Factorsmentioning
confidence: 99%
“…Then, 5 trials of maximum effort concentric knee flexion and extension at 60°/second were performed with verbal encouragement. To maximize reliability and validity, the data were "windowed" to remove acceleration and deceleration, thereby eliminating impact artifact (31,32). Only data recorded within 0.1°/second of 60°/second were included.…”
Section: Pathophysiologic Factorsmentioning
confidence: 99%
“…Previous isokinetic measures for concentric quadriceps peak torque at 60 deg.s Ϫ1 on the Biodex Isokinetic Dynamometer has demonstrated high test-retest intraclass correlation coefficients that ranged from 0.93 to 0.97. 9,12,32 Perceptually Guided Contractions. Immediately following the maximal effort contractions, subjects performed a series of perceptually guided contractions, with assistance from a modified category-ratio scale (CR-10) as developed by Borg.…”
Section: Measurement Of Knee Extensor Peak Torque and Workmentioning
confidence: 99%